20
Under all circumstances, make sure the induction hob is well ventilated and that the air inlet
and outlet are not blocked. Ensure the induction hob is in good working condition as shown
below.
Note: Leave a safety distance of at least 700 mm between the hotplate and the
cupboard above the hotplate.
If over the hob a hood is installed, keep as reference the distance indicated into the
hood user manual.
A(mm)
B(mm)
C(mm)
D
700
20 min.
20 min.
Air Intake
Before installing the hob, make sure that
the work surface is square and level, and no structural members interfere with the space
requirements
the work surface is made of heat-resistant material
if the hob is installed above an oven, the oven has a built-in cooling fan
the installation will comply with all clearance requirements and applicable standards
and regulations
a suitable isolating switch providing full disconnection from the mains power supply is
incorporated into the permanent wiring, and is installed and positioned in accordance
with the local wiring rules and regulations.
The is
olating switch must be of an approved type and provide a 3 mm contact separation (air
gap) on all poles (or all active [phase] conductors if the local wiring rules allow for this
var
iation of the requirements)
the customer will be able to access the isolating switch easily with the hob installed
you consult local building authorities and by-laws if in doubt regarding
installation