Replacethenozzleusingtheconversionset
suppliedwiththerangeorbyaBertazzoni
authorizedpartswarehouse.Eachnozzlehasa
numberindicatingitsflowdiameterprintedon
thebody.Consultthetableonpa ge 20for
matchingnozzlestoburners.
Adjusttheprimaryairflowbylooseningthescrew
PandsettingthegapXintheVenturiconeto½”
(5/16”fornaturalgas).
STEP4:BROILERBURNER
Loosenthescrewandpullouttheburnerfromits
support.
ATTENTION:payextraattentiontoavoiddamage
totheigniterandthermocouple.
Using a 7 mm [name of the tool] unscrew the
nozzle. Replace the nozzle using the conversion
set supplied with the range or by a Bertazzoni
authorized parts warehouse. Each nozzle has a
number indicating its flow diameter printed on
the body. Consult the table on page 20 for
matching
nozzlestoburners.
AdjustthegapXbysettingittofullyopen
position.