EasyManua.ls Logo

BFC GALILEO User Manual

BFC GALILEO
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
ISTRUZIONI X REGOLAZIONE TEMPERATURA CONTROLLO INDIPENDENTE
PER MODELLO GALILEO.
INSTRUCTIONS FOR REGULATING INDEPENDENT TEMPERATURE
CONTROL FOR GALILEO MODEL .
INSTRUCTIONS POUR LA RÈGOLATION DE LA TEMPERATURE CONTROL
INDIPENDENT POUR MODÈLE GALILEO.
INSTRUCCIONES PARA LA REGULACIÓN DE TEMPERATURA CONTROL
INDEPENDIENTE PARA MODELO GALILEO.
ANLEITUNG ZUM EINSTELLEN DER UNABHÄNGIGEN TEMPERATURANZEIGE
FÜR MODELLE GALILEO.
TCI + ES
TEMPERATURE CONTROL INDIPENDENT
+
ENERGY SAVING
TECNICO
TECHNICIAN
TECHNICIEN
TÉCNICO
TECHNIKER
ATTENZIONE: LE OPERAZIONI CONTENUTE IN
QUESTO MANUALE SONO CONSENTITE SOLO A
PERSONALE TECNICO QUALIFICATO.
WARNING: THE OPERATIONS INTO THIS
MANUAL ARE ALLOWED ONLY TO TECHNICAL
QUALIFIED.
ATTENTION: LES OPÈRATIONS CONTENU DANS
LE MANUEL SONT CONSENTIES SEULERENT À
TECHNICIENS QUALIFIÈS.
PRECAUCIÒN: LAS OPERACIONES
CONTENIDAS EN ESTE MANUAL SON PERMITE
SÓLO A PERSONAL TÉCNICO CUALIFICADO.
VORSICHT:
DIE VERHALTENEN OPERATIONEN
IN DIESES HANDBUCH ERLAUBTEN NUR ZU
TECHNISCHEN QUALIFIZIERT.
Question and Answer IconNeed help?

Do you have a question about the BFC GALILEO and is the answer not in the manual?

BFC GALILEO Specifications

General IconGeneral
BrandBFC
ModelGALILEO
CategoryCoffee Maker
TypeEspresso Machine
Pressure15 bar
MaterialStainless steel
ColorStainless steel

Summary

General Warnings and Precautions

Technical Qualification Required

Manual operations are permitted only for qualified technical personnel.

Main Switch Operation Positions

Switch Off Machine (Position 0)

Position 0: The coffee machine is switched off.

Water Fill and Heating Off (Position 1)

Position 1: Load water and power without boiler heating.

Half Power Boiler Heating (Position 2)

Position 2: Boiler heating and current at half power.

Full Power Boiler Heating (Position 3)

Position 3: Boiler heating and current at full power.

Heating Element Switch Operation

Half Power Heating for Boiler and Group

Switch for boiler and group heating at half power.

Full Power Heating for Boiler and Group

Switch for boiler and group heating at full power.

Resetting the Temperature Control Unit

Procedure to Reset Unit

Turn off, then turn on while holding the indicated button until 'PrS' appears.

Programming and Setting Parameters

Select Temperature Unit (°C / °F)

Choose between Celsius (°C) or Fahrenheit (°F) for temperature measurement.

Configure Proportional Control (P.)

Adjust the proportional control value (P.) for temperature regulation.

Configure Integral Control (I.)

Adjust the integral control value (I.) for error accumulation analysis.

Configure Derivative Control (d.)

Adjust the derivative control value (d.) for heating system evaluation.

Configure Boiler-Group Water Difference (°C)

Set parameter F.04 for the water temperature difference in Celsius.

Configure Boiler-Group Water Difference (°F)

Set parameter F.05 for the water temperature difference in Fahrenheit.

Saving Program and Handling Alarms

Save Program Settings

Shut down and restart the machine without pressing any buttons to save settings.

Alarm Codes and Meanings

Display shows 'A1' for disconnected probe, 'A2' for short circuit.