15
PARAMETERS SETTINGS
PARAMETER
DISPLAY
DESCRIPTION
F.03
°F
Measure unit Fahrenheit degree
°C
Measure unit Celsius degree
P. 1
Where 1 is the value of the constant proportional pid
control, which has the function to turn off and turn on the
heating element so that most closely matches the set
temperature value, more the impulse slows (otherwise the
value obtained should be to exceed the set value).
I. 0.00
Where 0.00 is the value of the constant integral pid
control, which has the function to calculate the
accumulation of error (in the case of a coffee machine is
very low), that is the analysis of the time remaining to
reach default.
d. 1.6
Where 1.6 is the value of the constant derivative pid
control, which has the function to evaluate the heating
system (that is, if the temperature is increasing or
decreasing) and based on this analysis decides the pulse
duration of the heating element.
F.04 22
Where 22 show the value that represent the difference
between the water temperature into the boiler and the
water coming out from the group during the coffee
dispensing ( This parameter is valid for the Temperature
in Celsius degree).
F.05 40
Where 40 show the value that represent the difference
between the water temperature into the boiler and the
water coming out from the group during the coffee
dispensing ( This parameter is valid for the Temperature
in Fahrenheit degree).
TO EXIT THE PARAMETER PROGRAMMING MODE TURN THE MACHINE OFF.