4) Check that the electronic appliance is correctly supplied. Check
the integrity of the fuses.
5) Check that the functions are correct by means of the control unit
dia-gnosing LEDs (see relevant instructions). Identify causes for
faults, if any. If the LEDs show persisting start control, check that
no radio controls, start buttons or other control devices keep the
start contact activated (closed).
6) If the control unit does not work, it must be replaced.
7) Check the movement of the cam-holder bars (g. 13), if it is not
smooth, the bars must be lubricated.
22.2) The bar does not open. The motor turns but there is no
movement.
1) The manual release was left engaged. Reset the motorised
operation.
2) If the release is in the motorised operation position, check the
gearmotor for integrity.
WARNINGS
Correct controller operation is only ensured when the data
contained in the present manual are observed. The company
is not to be held responsible for any damage resulting
from failure to observe the installation standards and the
instructions contained in the present manual.
The descriptions and illustrations contained in the present
manual are not binding. The Company reserves the right to make
any alterations deemed appropriate for the technical, manu-
facturing and commercial improvement of the product, while
leaving the essential product features unchanged, at any time
and without undertaking to update the present publication.
20 - MOOVI 30-50 - ALPHA BOM Ver. 05
D811471_05

Other manuals for BFT ALPHA BOM

Related product manuals