integrity of the fuses.
3) Check that the functions are correct by means of the control unit
diagnosing LEDs (see relevant instructions).
Identify causes for faults, if any. If the LEDs show persisting start control,
check that no radio controls, start buttons or other control devices keep
the start contact activated (closed).
4) If the control unit does not work, it must be replaced.
If after having carried out the checks listed above the problem persists,
replace the actuator.
21.2) The gate does not open. The motor turns but the movement does
not take place.
1) The manual release is activated. Reset the power-driven operation.
2) Check that the gate had reached the mechanical end-of-stroke stops.
Release and move the gate manually, and reset the power-driven
control. Check and correct the end-of-stroke bracket position.
3) Check that the mechanical setting of the gate is not defective, for
example if the wheels are blocked or the rack is not aligned with the
pinion, etc.
4) Check that the clutch does not slip. If it does, load it as described in the
relevant paragraph.
If after having carried out the checks listed above the problem persists,
replace the actuator.
WARNING! Correct controller operation is only ensured when the data
contained in the present manual are observed. The company is not to
be held responsible for any damage resulting from failure to observe
the standards relating to safety, installation and good technical
practice, as well as the instructions contained in the present manual.
The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any altera-
tions deemed appropriate for the technical, manufacturing and com-
mercial improvement of the product, while leaving the essential
product features unchanged, at any time and without undertaking to
update the present publication.