ACCESS MENUS Fig. 1
Exit Menù
Conrm/Switch on display
Scroll up
Scroll down
See PARAMETERS MENU
See LOGIC MENU
language
stat
-
+
OK
vers
bft . . .
+/-
OK
0000
+/-
n. cycles
OK
01.33
-
+
err
02.01
........
30.15
+/-
List of last 30 errors
Control unit software version
No total
manoeuvres (in hundreds)
ALT follow the user guide
x2
0---
10--
150- 1520 ok
*** Password entry.
Request with Protection Level
logic set to 1, 2, 3, 4
***
password
0---
10--
150- 1520 prg
Diagnostics code DESCRIPTION NOTES
STRE
START E external start input activated
STRI
START I internal start input activated
OPEN
OPEN input activated
CLS
CLOSE input activated
PED
PED pedestrian input activated
TIME
TIMER input activated
STOP
STOP input activated
PHOT
PHOT photocell input activated
PHOP
PHOT OP opening photocell input activated
PHCL
PHOT CL closing photocell input activated
BAR
BAR safety edge input activated
BAR 2
BAR safety edge input activated on slave motor
(opposite leaves connection)
bar c
Closing safety edge input activated
bar o
Opening safety edge input activated
SWC
SWC motor closing limit switch input activated
SWO
SWO motor opening limit switch input activated
rls
Mechanical release activated Check position of release
ER01
Photocell test failed
Check photocell connection and/or logic settings
ER02
Safety edge test failed
Check safety edge connection and/or logic settings
ER03
Opening photocell test failed
Check photocell connection and/or parameter/
logic setting
ER04
Closing photocell test failed
Check photocell connection and/or parameter/
logic setting
ER06
8k2 safety edge test failed
Check safety edge connection and/or parameter/
logic settings
ER07
Opening safety edge test failed
Check safety edge connection and/or parameter/
logic settings
ER08
safety edge test failed
Check safety edge connection and/or parameter/
logic settings
ER1x
*
Board hardware test error
- Check connections to motor
- Hardware problems with board (contact technical
assistance)
ER4x
*
Thermal cutout Allow automated device to cool
ER70-ER71
ER74-ER75
Internal system supervision control error.
Try switching the board o and back on again. If
the problem persists, contact the technical assis-
tance department.
ER72
Consistency error of the control unit’s parameters
(Logics and Parameters)
Pressing OK the detected settings are conrmed. The
board will keep on working with the detected settings.
The board settings must be checked (Parameters
and Logics)
ER73
D-track parameter error
Pressing OK, the board will keep on working with
D-track as a default.
An autoset is required
ErFx*
limit switch error check limit switch connections
ERF3
error in setting SAFE inputs Check the correct setting of the SAFE inputs
*X= 0, 1, .., 9, A, B, C, D, E, F