x Before use, verify the meter's operation by measuring a known voltage.
x When servicing the meter, use only specified replacement parts.
x Use caution when working with voltage above 30V ac rms, 42V peak, or 60V dc. Such voltages
pose a shock hazard.
x When using the probes or meter, keep your fingers behind the finger guards on the probes or the
meter.
x Connect the common test lead before you connect the live test lead. When you disconnect test
leads, disconnect the live test lead first.
x Remove the test leads from the meter and remove the clamp Jaws from the conductor under test
before opening the case or the battery cover.
x Do not operate the meter with the battery cover or portions of the case removed or loosened.
x To avoid false readings, which could lead to possible electric shock: or personal injury, replace the
batteries as soon as the low battery indicator
appears.
x To avoid electric shock, do not touch any naked conductor with hand or skin.
x Do not hold the meter anywhere beyond the tactile barrier.
x Adhere to local and national safety codes. Individual protective equipment must be used to
prevent shock and arc blast injury where hazardous live conductors are exposed.
x Remaining endangerment:
When an input terminal is connected
to dangerous live potential it is to be noted that
this potential at all other terminals can occur!
x CAT 11 - Measurement Category 11 is for measurements performed on circuits directly connected
to low voltage installation. Examples are measurements on household appliances, portable tools
and similar equipments. Do not use the meter for measurements within Measurement Categories
III and IV.
CAUTION
To avoid possible damage to the meter or to the equipment under test follow these guidelines:
x Disconnect circuit power and discharge all capacitors before testing resistance, diode and
continuity.
x Use the proper function and range for your measurements.
x Before rotating the function/range switch to change functions, remove test leads from the circuit
under test and remove the jaws from the clamped conductor.
ELECTRICAL SYMBOLS
Alternating Current
Direct Current
Caution, risk of danger, refer to the operating manual before use.
Caution, risk of electric shock.
Earth (ground) Terminal
Conforms to European Union directives
The equipment is protected throughout by double insulation or reinforced Insulation.