User’s Manual IUPS-401-Series
Status display and Alarm
Status display Alarm Alarm sound LED
detachable
Normal UPS mode – green
Battery charge (mains mode) – green flashing
UPS battery mode 2 beep sounds every 3 seconds yes red flashing
UPS battery mode (Battery low) 4 beep sounds a second no red flashing (quickly)
Overload (Normal mode) Continuous sound no red
Internal UPS failure 8 beep sounds per 2 sec., no red flashing (quickly)
2 sec. stillness
Overtemperature 8 beep sounds per 2 sec., yes red flashing (quickly)
2 sec. stillness
Battery defect – red flashing (quickly)
Model overview IUPS-401-110-B7
Article Interface Load sensor UPS management software
No. switch off
IUPS-401-110-B7 SERIAL (D-SUB) ≤33 W*
Reboot function
RUPS 2000 OEM, UPS management
software, included in delivery.
If mains voltage returns after a power failure while Windows® is already shutting down, the UPS switches the
PC off (after the shut-down period) and switches it on again after approximately 5 seconds in conjunction
with RUPS 2000 and an ACPI-PC. Observe BIOS settings of mainboard.
* Tolerance of switch-o threshold ≤3 %
For futher information please visit our website www.bicker.de and refer to the article number.