1
CHECKLIST
DO
Read the Operation and Maintenance Manual.
Check all hose connections.
Use a 12 gauge cord if the cord is under 50 ft (15 m) or a 10 gauge cord if the cord
is over 50 ft (15 m).
Provide fresh air intake for the cooler and maintain a minimum clearance of 3 ft
(0.9m) behind the cooler.
Flush new cooling media.
1. Fill the cooler with water.
2. Switch on the pump.
3. Run the cooler without the fan running for 5 hours.
Make sure the cooling media is being evenly saturated by using the control valve
to adjust the water flow.
Drain and clean the cooler weekly. Remove the cooling media and wash with a
garden hose.
Use Refresh™ tablets (algae killer) and/or CTT-EC™ cooler treatment tablets
(mineral treatment). One algae killer tablet is provided in the cooler's reservoir.
Additional water treatment tablets are available at bigassfans.com.
DO NOT
Χ DO NOT forget to dry out the cooling media before shutting down the cooler. Turn
o the pump and leave the fan running for 10 to 15 minutes.
Χ DO NOT run the pump without filling the reservoir with water first.
Χ DO NOT completely open the water valve. This may flood the cooling media.
Χ DO NOT use a water source with more than 120 PSI (8 bar/827 kPa) of water
pressure.
Χ DO NOT operate the cooler in a sealed room. Allow for fresh air intake and
exhaust.