WWW.BIGASSFANS.COM © 2020 DELTA T LLC ALL RIGHTS RESERVED.
1
CHECKLIST
DO
✓ Read the Operation and Maintenance Manual.
✓ Check all hose connections.
✓ Use a 12 gauge cord if the cord is under 50 ft (15 m) or a 10 gauge cord if the cord
is over 50 ft (15 m).
✓ Provide fresh air intake for the cooler and maintain a minimum clearance of 3 ft
(0.9m) behind the cooler.
✓ Flush new cooling media.
1. Fill the cooler with water.
2. Switch on the pump.
3. Run the cooler without the fan running for 5 hours.
✓ Make sure the cooling media is being evenly saturated by using the control valve
to adjust the water flow.
✓ Drain and clean the cooler weekly. Remove the cooling media and wash with a
garden hose.
✓ Use Refresh™ tablets (algae killer) and/or CTT-EC™ cooler treatment tablets
(mineral treatment). One algae killer tablet is provided in the cooler's reservoir.
Additional water treatment tablets are available at bigassfans.com.
DO NOT
Χ DO NOT forget to dry out the cooling media before shutting down the cooler. Turn
o the pump and leave the fan running for 10 to 15 minutes.
Χ DO NOT run the pump without filling the reservoir with water first.
Χ DO NOT completely open the water valve. This may flood the cooling media.
Χ DO NOT use a water source with more than 120 PSI (8 bar/827 kPa) of water
pressure.
Χ DO NOT operate the cooler in a sealed room. Allow for fresh air intake and
exhaust.