ENGLISH
Code 81320341 - 1/1/2010 WEIGHING TERMINAL QUICK START
ON/OFF
85-265 Vac
50/60 Hz
BAF
A C F
B
D E
D400
2. Display and keyboard
1. Unpacking and Installation
*
Not included
Remove terminal
from pack along with
the CD containing
the instructions.
Connect in
sequence.
A. Weighing plat-
form.
B. Any peripheral
equipment used
(e.g.: print-
ers, additional
displays, etc.).
C. Optional outputs
(e.g.: Ethernet,
WI-FI, I/O, BCD,
R232/422/485).
D. Analog output.
E. I/O connection.
F. Mains power
socket. Check
voltage value on
data plate.
*
*
Stable weight Center zero
Tare
Tare entered
via keyboard
Gross weight
Gross weight
in pounds
Minimum
weight
Net weight
Weighing range
indication
Below-range
weight indica-
tion
Within-range
weight indica-
tion
Above-range
weight indica-
tion
Weight reset
Tare entry and
cancellation
Tare entry and
display
Printing and/or
transmission
start
Customizable
keys
I
on
O
off
Press button I to
turn the terminal
on.
Press button O to
turn the terminal
off.

Other manuals for Bilanciai D400

Questions and Answers

  • R
    Robert TaylorAug 17, 2025
    What to do if Bilanciai D400 Touch terminals show RAM checksum error?
    • C
      Carol GardnerAug 17, 2025
      If your Bilanciai Touch terminals display a RAM checksum error, it indicates an error in the RAM. The suggested solution is to replace the CPU board.
  • I
    ifloresAug 20, 2025
    What to do if Bilanciai D400 Touch terminals display program checksum error?
    • M
      Mary MelendezAug 20, 2025
      If your Bilanciai Touch terminals show a program checksum error, this indicates an error in the program memory. The suggested solution is to replace the CPU board.
  • M
    Mr. Stephen MartinAug 22, 2025
    What causes parameters memory error in Bilanciai D400 Touch terminals?
    • C
      Cameron SummersAug 22, 2025
      A parameters memory error in Bilanciai Touch terminals is caused by an error in the data contained in the parameters memory of the board. To resolve this, check the linearized calibration parameters.
  • C
    Cory BurnsAug 25, 2025
    What to do if Bilanciai Touch terminals show digital cell powering fault?
    • M
      Miss Donna ThompsonAug 26, 2025
      If your Bilanciai Touch terminals display a digital cell powering fault, replace the load cell that signals the error.
  • A
    Andre ZunigaAug 27, 2025
    What to do if Bilanciai Touch terminals show converter fault?
    • T
      Thomas MaxwellAug 27, 2025
      If your Bilanciai Touch terminals display a converter fault, it could be due to several reasons. First, check the load cell connection for any faults in the extension lead, junction box, or the load cells themselves. Another cause might be a return signal from the load cell being greater than approximately +23 mV or less than approximately -23 mV; in this case, verify that the load cell is in good working order and within its specified range. A faulty converter board could also be the reason. You can check the converter board using a load cell simulator. If necessary, replace the converter board and/or the CPU. Finally, if digital cells fail to respond, check the cell connections.
  • P
    Paul MartinezAug 30, 2025
    What to do if Bilanciai Touch terminals show serial number error on digital cell?
    • A
      Anthony LeeAug 30, 2025
      To address a serial number error on a digital cell in Bilanciai Touch terminals, check the serial numbers and calibrate the angles if necessary.
  • S
    Sara AllisonSep 1, 2025
    What to do if a cell is broken in a Bilanciai D400 multi-cell system?
    • J
      Jeff LiSep 1, 2025
      If a cell is broken in a multi-cell system of Bilanciai Touch terminals, replace the cell and calibrate the angles.
  • E
    Emily McleanSep 4, 2025
    What to do if the CPU board is broken in Bilanciai Touch terminals?
    • B
      Betty SmithSep 4, 2025
      If the CPU board is broken in your Bilanciai Touch terminals, replace the CPU board and calibrate the angles or reset terminal data if they were saved before the board broke.
  • T
    tonyawebsterSep 6, 2025
    What to do if Bilanciai D400 show cell with internal temperature off-limits?
    • S
      Shaun WilliamsSep 7, 2025
      If a Bilanciai Touch terminals display a cell with an internal temperature off-limits, replace the cell that signals the error and calibrate angles for the replaced cell.
  • B
    Brittany CruzSep 9, 2025
    What to do if at least one cell is not configured on Bilanciai D400 Touch terminals?
    • H
      Hunter PetersonSep 9, 2025
      If at least one cell is not configured on your Bilanciai Touch terminals, calibrate the angles.

Summary

Unpacking and Installation

Connection Points Overview

Details the various connection points for external devices and power supply.

Display and Keyboard Functions

Explains the meaning of symbols and indicators on the terminal's display and keyboard.

Weighing and Tare Entry Procedures

Resetting the Terminal

Procedure to reset the weighing terminal to its default state.

Tare Entry Process

Step-by-step guide for entering tare values for weighing.

Printing and Data Transmission

Instructions for printing or transmitting weighing data to a PC.

Menu Navigation and Setup

Menu Browsing Controls

Explains how to navigate through the terminal's programming menus using specific keys.

Setup Menu Options

Details available setup options, including contrast, date/time, and display settings.

Bilanciai D400 Specifications

General IconGeneral
BrandBilanciai
ModelD400
CategoryTouch terminals
LanguageEnglish

Related product manuals