User guide
Billi Quadra & Quadra Sparkling Plus – XL.
9
Removing the CO
2
cylinder
1. Isolate the water supply and turn o
the power.
This will prevent the internal pump
from pressurizing the system.
2. Turn o the CO
2
regulator by turning the
black knob anti-clockwise.
3. Drain any remaining pressure by activating
the sparkling water option on the dispenser
installed.
Ensure the pressure gauge shows near to
zero pressure – if the pressure is less than
one bar, and the dial is fully anti-clockwise,
then the cylinder can be removed with only
a small amount of CO
2
escaping
4. Hold the regulator and rotate the Cylinder
clockwise to remove.
If the bottle is not empty, CO
2
may escape
while you are turning the bottle. The bottle
will self-seal prior to the thread being free
from the regulator.
Avoid breathing air containing CO
2
or
contact with the cold escaping gas as
per the Safety Data Sheet.