POOL COUNTERFLOW UNIT
BGA 160, BGA 215, BGA 275,
BGA 320, BGA 430, BGA 550

Questions and Answers

  • T
    Thomas JacksonJul 25, 2025
    Why won't my Binder HydroStar BGA 320 Water System turbine start?
    • K
      keith82Jul 25, 2025
      Your Binder Water System turbine might not start due to several reasons: the residual current device may be switched off (switch it on), the building fuse may have tripped (replace the fuse), or the range of the radio transmitter might be insufficient (move closer to the control unit or install the receiver outside).
  • T
    Troy DavisJul 31, 2025
    What to do if the red LED is flashing on my Binder HydroStar BGA 320 motor control unit?
    • D
      Donna MillerJul 31, 2025
      If the red LED on your Binder Water System motor control unit is flashing, it could be due to a few reasons. The motor may be blocked by material in the turbine (remove the cover plate and clear any obstructions), the motor supply line might be disconnected (check and repair the connection), or there could be corrosion on the contact points (inspect, clean, and reconnect all screw and soldered connections on the motor cable).
  • J
    Jared MillerAug 6, 2025
    How to fix a Binder HydroStar BGA 320 Water System turbine that won't operate with the radio transmitter?
    • C
      Cindy PattersonAug 7, 2025
      If your Binder Water System turbine cannot be operated with the radio transmitter, the battery in the transmitter may be weak or inserted incorrectly (check and replace if necessary). Alternatively, if the transmitter was under water, remove the battery and let it dry for 48 hours at room temperature with the battery compartment open. If it still doesn't work, use a new transmitter.
  • I
    icollinsAug 13, 2025
    Why does the fuse in the building distributor box trip when I switch on my Binder HydroStar BGA 320 Water System?
    • J
      Joel MorganAug 13, 2025
      If the fuse in the building distributor box trips when switching on your Binder Water System, it may be due to an incorrect or fast-acting fuse. Use a 16A slow-blow fuse instead.
  • K
    Kathy RichAug 18, 2025
    What to do if my Binder HydroStar BGA 320 Water System turbine pumps in the wrong direction?
    • L
      Luke JamesAug 18, 2025
      The motor connection of your Binder Water System may be incorrect. Check and correct the control unit's motor connection.

Summary

General Information and Safety

Important Information and User Guidance

Crucial details for operation, warranty, user roles, and technical data overview.

Hazard Information and Safety Precautions

Critical safety warnings for rotating parts, electrical hazards, and general safety notes.

Proper Use and Operating Conditions

Outlines intended uses, environmental parameters, and correct operation guidelines.

Disposal and Scope of Supply

Guidelines for environmentally sound disposal and listing of included components.

HydroStar Installation Procedures

Installation Shaft Scope of Supply

Lists components included with the HydroStar installation shaft.

Pool Installation for BGA Models

Details for installing BGA 160/215/275 and BGA 320/430/550 models in pools.

Flange, Turbine Alignment, and Cover Plate Installation

Steps for fitting the spring-loaded flange, aligning the turbine, and attaching the cover plate.

Turbine Installation Without Dedicated Shaft

Illustrates installation examples and provides dimensions for turbines without a dedicated shaft.

Retrofit and Accessory Installation

Retrofit Installation Guidelines

Notes on mounting units in existing pools, frame attachment, and suction slits.

PIEZO Tri and PIEZO Tri Square Installation

Details for installing the PIEZO Tri unit in a pool wall and its square variant.

Control Unit and Electrical Connections

Control Unit Installation and Safety

Safety regulations and mounting instructions for the control unit.

Connection Block Diagram and Terminals

Overall wiring illustration and details on WAGO terminals for connections.

Motor and PIEZO Tri Wiring

Procedures for connecting the motor cable, supply line, and PIEZO Tri.

System Operation and Control

Start-Up and Remote Control Operation

Steps for safely turning on the unit and operating via radio remote control.

Remote Control Functions

How to switch the turbine on/off and control water jet flow using the remote.

Optional Operation via PIEZO Tri and Touch Display

Using PIEZO Tri interface and touch display for system control.

Maintenance, Shutdown, and Troubleshooting

End of Operation and Winter Shutdown

Procedures for daily shutdown and protecting the unit during winter.

Maintenance and Repair Procedures

Guidelines for routine maintenance, inspections, and repairs.

Troubleshooting Guide

Lists common malfunctions, causes, and resolutions for diagnosing issues.

Document Revisions

Revision History

Records of updates and changes made to the document over time.

Recommended Water Properties

Water Quality Parameters

Specifies ideal pH, chlorine, salt concentration, and other water parameters.