SB-6-HGBR-R1 (3/2018) 1 / 6 www.carlisleft.com
II2G
DESCRIPTION
The fluid pressure relief valve can be used
in 2 functions:
In « circulating » system as a back
pressure valve to maintain system
and maintain material fluid flow
when no material is being used.
As by-pass valve to protect against
excessive line pressure, the result of
either material flow exceeding valve
capacity or the result of a restriction
in the line beyond the by pass valve.)
A Manual Adjustment Key E Fluid outlet
B Spring F Fluid Inlet
C Diaphragm Assembly G Riser tube
D Valve stem H Manometer
SPECIFICATIONS
The fluid passages of this Fluid Pressure
Relief Valve are in stainless steel (303).
This HGBR regulator is equipped with a
manual spring adjusting pressure system.
The manometer is fitted on a riser tube and
tee connection in stainless steel material.
This HGBR regulator is suitable for use
with halogenated hydrocarbons and user
must ensure that all other equipment in
the system is also suitable for use with this
material.
IMPORTANT: This Fluid Pressure Relief
Valve may be used with most common
coating and finishing material. However,
they are not designed for use with highly
corrosive or highly abrasive materials.
If used with materials which have such
characteristics, it must be expected
that frequent and thorough cleaning
will be required and/or the necessity for
replacement of parts will be increased.
If there is any doubt about the suitability
of the HGBR for a particular material,
inform your local DeVilbiss distributor
what material is to be used, or submit a
sample of such material for test.
Order number
Thread
Inlet pressure
min-max.bar
Outlet pressure
max.bar
Fluid flow
maximum
L/min
Manometer
bar
Inlet Outlet
HGBR - 609
Female
1/4
Female
1/4
2 / 12,5 0 / 9 18 0 – 10
EN
SERVICE MANUAL
HGBR-609 FLUID REGULATOR
Temperature range: 0° – 50°C (32° – 122°F)
Question and Answer IconNeed help?

Do you have a question about the Binks HGBR-609 and is the answer not in the manual?

Binks HGBR-609 Specifications

General IconGeneral
BrandBinks
ModelHGBR-609
CategoryController
LanguageEnglish

Summary

HGBR-609 Fluid Regulator Overview

Critical Safety Warnings and Precautions

Fire, Explosion, and Solvent Hazards

Covers flammability, ventilation, and specific solvent risks.

Static Electricity and Grounding Requirements

Addresses static discharge risks and necessary grounding.

Personal Protective Equipment (PPE) Guidance

Recommends appropriate PPE for safe operation.

Installation, Operation, and Maintenance

Parts Identification and Ordering

Troubleshooting and Part Replacement

Diaphragm Replacement Guide

Step-by-step instructions for replacing the diaphragm assembly.

Valve Assembly Servicing Procedures

Instructions for maintaining and servicing the valve assembly.

Common Defects and Correction Methods

Lists issues, causes, and recommended solutions.