EasyManua.ls Logo

Binks 84-598 - User Manual

Binks 84-598
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Replaces
Part Sheet
77-2871
Part
Sheet
77-2871
INTRODUCTION
The Binks Models 84-598 and 84-599 Remote Fluid
Pressure Regulators are designed for use with Manual or
Automatic Spraying Systems utilizing an I/P (current to
pressure) or E/P (voltage to pressure) Transducer and where
precise fluid pressure outputs to spray gun are required.
The flow rate for model 84-598 is rated at 30 oz./min.
The flow rate for model 84-599 is rated at 100 oz./min.
ADVANTAGES
1. Accurate and repeatable fluid flows with maximum
control sensitivity.
2. Small plastic fluid cavity for rapid cleanout and color
flush cycles.
3. Positive spring-loaded shut-off (no leakage).
4. Designed to protect electronic transducer control systems
(independent vented air chamber).
5. Can be used on open and closed loop fluid pressure
control systems.
6. Maximum corrosion and solvent resistance.
7. Contains air gap to permit indication of air or fluid
diaphragm failure.
8. Contains carbide seats and valves.
SET-UP INSTRUCTIONS
The fluid inlet is fitted into the regulator body with a 3/8"
NPT(m) (standard), 3/8" NPS(m) (optional) swivel nut
connection. The fluid outlet connection is 3/8" NPS(m).
The control air inlet is 1/8" NPT(f).
The regulator may be mounted in either a horizontal or
vertical position. As little as 4 PSI control air pressure will
open this regulator depending on fluid pressure supply.
PRESSURE AND FLOW DATA
Regulation Range (Control Air) 4-100 psi 7.03 kg/cm
2
Maximum Fluid Inlet Pressure 200 psi 14.06 kg/cm
2
Control Ratio (approx.) 1:1
Binks Models 84-598 & 84-599
REMOTE FLUID PRESSURE
REGULATORS
(30oz. / min. & 100oz. / min.)
CONTROL
AIR INLET
1/8" NPT(f)
UNREGULATED
FLUID INLET
3/8" NPT(m)
(STANDARD)
3/8" NPS(m)
(OPTIONAL)
REGULATED
FLUID OUTLET
3/8" NPS (m)
DIMENSIONS
APPROX.
13/16"
APPROX. WT. 1.85 LBS.
4-1/4"
3-1/2"
Question and Answer IconNeed help?

Do you have a question about the Binks 84-598 and is the answer not in the manual?

Summary

Introduction and Overview

Binks Models 84-598 & 84-599 Remote Fluid Pressure Regulators

Describes the purpose and application of Binks Models 84-598 & 84-599 regulators for spraying systems.

Key Advantages of the Regulators

Lists benefits including accurate flow, rapid cleanout, positive shut-off, system protection, and durability.

Setup Instructions for Fluid and Air Connections

Details fluid and air connection specifications and mounting orientation.

Pressure and Flow Data Specifications

Provides regulation range, maximum inlet pressure, and control ratio.

Safety Warnings and Precautions

Understanding Warning, Caution, and Note Designations

Explains the meaning of WARNING, CAUTION, and NOTE for safety information.

Essential Safety Practices Before Operation

Covers manual reading, safety glasses, power lockout, operator training, guards, and emergency shutdown.

Specific Hazard Alerts

Details risks of equipment misuse, high pressure, electrical shock, projectiles, fire, explosion, and static charge.

Equipment Inspection and Modification Policy

Recommends daily inspection and prohibits unauthorized modifications.

Recommended Configurations and Service

Recommended Maximum Fluid Flows by Model

Specifies parts for Model 84-598 (low/medium viscosity) and 84-599 (high viscosity).

Service Instructions: Replacing Fluid Valve, Seat, and Gasket

Step-by-step guide for removing and replacing fluid valve components.

Service Instructions: Reassembly Procedures

Instructions for reassembling the regulator after component replacement.

Service Instructions: Replacing Diaphragms

Procedure for removing and replacing internal diaphragms.

Technical Diagrams and Specifications

Service Diagram and Torque Specifications

Illustrates regulator components and lists required torque for specific items.

Detailed Parts List and Identification

Binks Models 84-598 & 84-599 Parts Identification

Diagram showing numbered parts with corresponding part numbers and descriptions.

Parts List for Ordering

Comprehensive list of all available parts with part numbers for ordering.

Control Method Diagrams

Manual Control Method - Open Loop

Schematic illustrating manual control of the regulator in an open-loop system.

Automatic Control Method - Open Loop

Schematic showing automatic control in an open-loop system with I/P or E/P transducer.

Advanced Control Method Diagram

Automatic Control Method - Closed Loop

Diagram detailing automatic closed-loop control using a controller and flow meter.

Warranty and Contact Information

Product Warranty Coverage

States that the product is covered by Binks' 1 Year Limited Warranty.

Worldwide Sales and Service Listing

Provides website for Binks worldwide sales and service information.

ITW Industrial Finishing Technical Service Office

Lists the U.S./Canada Technical Service Office address and contact numbers.

Binks 84-598 Specifications

General IconGeneral
BrandBinks
Model84-598
CategoryController
LanguageEnglish

Related product manuals