EasyManua.ls Logo

Bio-Logic VMP-300-based User Manual

Default Icon
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation and
Configuration Manual
for VMP-300-based* Instruments
and Boosters
*VMP300-based instruments are:
SP-200
SP-240
SP-300
VSP-300
VMP-300
HCV-3048

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Bio-Logic VMP-300-based and is the answer not in the manual?

Bio-Logic VMP-300-based Specifications

General IconGeneral
BrandBio-Logic
ModelVMP-300-based
CategoryMeasuring Instruments
LanguageEnglish

Summary

Safety and Legal Information

Intended Use of Equipment

Describes the purpose of the equipment and its intended applications.

General Operating Instructions

Provides essential instructions for safe and proper operation.

Grounding Safety Precautions

Details the importance and procedure for grounding the instrument.

Environmental Operating Conditions

Specifies atmospheric and temperature requirements for safe use.

Avoiding Unsafe Equipment

Lists criteria that may render the equipment unsafe for use.

Live Conductor Safety

Highlights risks associated with live conductors and maintenance.

Equipment Modification Warnings

Advises against unauthorized modifications to maintain safety.

General Safety Information

Explains safety classifications and general precautions.

Warning and Caution Notice Definitions

Clarifies the meaning and implications of warning and caution notices.

Introduction to Product Range

Instruments Description Overview

Provides a general overview of the VMP300-based instrument family.

Single/Multichannel & Booster Instruments

Details descriptions of single and multichannel instruments with boosters.

VMP-300 Slot Numbering

Describes the slot numbering scheme for the VMP-300 instrument.

HCV-3048 External Booster

Introduces the HCV-3048 as a high-power external booster.

Getting Started

Hardware Installation Procedure

Outlines the steps for installing the instrument hardware.

Preparation for Physical Installation

Lists checks required before physical installation.

Safety Emergency Shutdown

Explains the emergency stop function of the HCV-3048.

Ventilation Requirements

Details the importance of proper airflow and cooling.

Unpacking and Inspection Process

Steps for unpacking and inspecting the instrument.

Electrical Requirements

Specifies the electrical input and fuse requirements.

Safety Precautions During Setup

General safety guidelines to follow during setup.

Communication Connection Methods

Describes methods for connecting the instrument to a PC.

Network Connection Configuration

Details how to establish network connections.

Software Installation and PC Configuration

EC-Lab® Software Installation

Step-by-step guide for installing the EC-Lab® software.

EC-Lab® Express/OEM Package Installation

Instructions for installing optional Express or OEM software packages.

Installation Error Troubleshooting

Guidance on resolving common installation errors.

PC Installation and TCP/IP Configuration

Steps for PC setup and TCP/IP configuration for communication.

USB Driver Installation Procedures

Instructions for installing USB drivers for instrument connection.

Firmware Upgrading and Downgrading

Procedures for managing instrument firmware versions.

Connecting the PC to the Instrument

Ethernet Connection Configuration

Setting up network parameters for Ethernet communication.

Connecting via EC-Lab® Software

Guide to connecting the instrument using the EC-Lab® software.

Modifying Instrument IP Address

Steps to change the instrument's IP address for network connectivity.

Connecting via EC-Lab® Express Software

Guide to connecting the instrument using EC-Lab® Express software.

Connection to the Cell

Cell Cable to Instrument Connection

Describes how to connect the cell cable to the instrument.

Cell Cable and Board Association

Explains the importance of pairing cables with specific boards.

Instrument Boards Description

Details on the different types of boards used in the instruments.

Booster Boards Overview

Describes the different types of booster boards available.

HCV-3048 Booster Chassis Details

Specific information about the HCV-3048 booster.

Connecting Cell Cable to Your Cell

Instructions for connecting the cell cable to the experimental setup.

Standard Cable Description

Details on the standard cell cable.

Standard Connection Configurations

Explains common standard connection methods for cells.

Two-Electrode Connection Method

Specifics for connecting a two-electrode cell.

Four-Electrode Connection Method

Specifics for connecting a four-electrode cell.

CE to Ground Connection Mode

Describes the CE to Ground connection setup.

WE to Ground Connection Mode

Describes the WE to Ground connection setup.

High Voltage Control Connection Mode

Describes connection for high voltage control.

Floating Mode Operation

How to use the instrument in floating mode.

High Current Booster Connections

Specifics for connecting high current boosters.

Auxiliary Input/Output (DB9) Functions

Explains the use of the DB9 connector for auxiliary signals.

Advanced Features

Bandwidth Selection Guidance

Information on selecting appropriate bandwidth settings.

Floating Mode Operation

How to configure and use the floating mode.

Filtering Options

Using filters to improve measurement quality.

External Device Control and Recording

Integrating and recording data from external devices.

Rotating Electrode Control

How to control rotating electrodes with the instrument.

Temperature Control Integration

Using external thermostats for temperature management.

EQCM Coupling Procedures

Connecting and configuring Electrochemical Quartz Crystal Microbalances.

Virtual Potentiostat Usage

Using the software as a virtual instrument for offline analysis.

Options & Accessories

Analog Ramp Generator (ARG)

Description and specifications of the ARG option.

Isolation System (IS1)

Details on the IS1 isolation system for maintaining floating character.

Current Collector (CC5)

Explanation of the CC5 for connecting multiple boosters.

MP-MEA Option

Dedicated option for micro electrode array applications.

Test Boxes for Calibration & Training

Overview of test boxes for instrument setup and user training.

Dummy Cell 2 (DC2) Description

Details on the DC2 dummy cell.

Booster Dummy Cell

Description of the dummy cell for booster calibration.

Test Box 2 for Calibration

Usage of Test Box 2 for calibrating channel boards.

Test Box 3 for Practice

Usage of Test Box 3 for practicing electrochemical systems.

Temperature Probe Usage

How to use the temperature probe with the instrument.

Battery Holder BH-1

Description of the BH-1 battery holder.

LabVIEW VI Integration

Information on integrating with LabVIEW using VIs.

Electrochemistry Accessories List

Reference to other available accessories.

Validation and Calibration

Channel Validation Procedures

Steps to validate the instrument's channels.

Channel Validation without EIS

Validation steps for channels not equipped with EIS.

Channel Validation with EIS

Validation steps for channels equipped with EIS.

Ultra-Low Current Module Validation

Procedures to validate the ULC module.

Booster Board Validation

Steps for validating booster boards.

Channel Calibration with EC-Lab®

Detailed guide for calibrating channels using EC-Lab® software.

Potentiostat/Galvanostat Board Calibration

Specific calibration process for PSTAT/GSTAT boards.

Booster Board Calibration Process

Step-by-step guide for calibrating booster boards.

HCV-3048 Booster Calibration

User calibration procedure for the HCV-3048 booster.

Technical Specifications

Equipment Ratings Overview

General ratings for the instruments.

Electrical & Mechanical Specifications

Detailed electrical and mechanical specifications.

Environmental Specifications

Environmental operating conditions and compliance.

Channel Specifications Details

Specifics for channel boards and their functions.

Ultra Low Current Specifications

Performance specs for the ULC option.

1A/48V Booster Specifications

Performance specs for the 1A/48V booster.

2A/30V Booster Specifications

Performance specs for the 2A/30V booster.

4A/14V Booster Specifications

Performance specs for the 4A/14V booster.

10A/5V Booster Specifications

Performance specs for the 10A/5V booster.

HCV-3048 with HV-48 Electrometer Specs

Performance specs for HCV-3048 with HV-48.

MP-MEA Option Specifications

Performance specs for the MP-MEA option.

PC System Requirements

Minimum PC specifications needed for the software.

Troubleshooting

Data Saving Problem Solutions

Steps to resolve issues with saving experimental data.

PC Disconnection Troubleshooting

Solutions for problems with PC-instrument disconnection.

Computer Power Saving Impact on Data

Advice on disabling power saving features to ensure data recording.

EC Declaration of Conformity

SP-200 Declaration of Conformity

CE declaration for the SP-200 model.

SP-240/SP-300 Declaration of Conformity

CE declaration for SP-240 and SP-300 models.

VSP-300 Horizontal Declaration of Conformity

CE declaration for the Horizontal VSP-300.

VSP-300 Vertical Declaration of Conformity

CE declaration for the Vertical VSP-300.

VMP-300 Declaration of Conformity

CE declaration for the VMP-300 model.

HCV-3048 Declaration of Conformity

CE declaration for the HCV-3048 model.

Glossary

Glossary of Technical Terms

Definitions of terms used throughout the manual.

Index

Document Index

Alphabetical listing of topics covered in the manual.

Related product manuals