time, about 2 seconds start to countdown according to the new time.
4.3 Reset the display time after pressing +/- at the same time.
5. Fault code table
E1
E2
HOT
Hall transducer is abnormal
(Signal line broken or motor
blocked)
NTC signal is abnormal
(Signal line is disconnected
and motor working
temperature is not
detected)
Motor overheat
protection
(Automatic recovery after
cooling)
6. Clean/wash
6.1 Before cleaning the machine, ensure that the speed knob is closed, and unplug the
power cord, and clean the machine after cooling.
6.2 When cleaning the outside of the machine, you can use dry or wet cloth and a little
cleaning agent to clean, but do not let water or cleaning agent into the machine, so as
not to damage the parts or cause the risk of electric shock.
6.3 Do not clean the inside and outside of the machine with abrasive or alcohol.
6.4 Do not wash the machine submerged in water.
6.5 Please pay attention to avoid sharp parts or rotating parts damage in the cleaning
process, should be careful operation.
6.6 Stainless steel bowl should be especially careful when cleaning, please use below 40
degrees of warm water and neutral detergent cleaning, do not use abrasive or other
with special acid/alkali composition of the lotion cleaning.