www.biopac.com 1
MP System Hardware Guide
The MP Hardware Guide describes how to connect and set up various signal conditioning and amplifier
modules for use with the MP System, and includes sections that detail different applications and uses for the
MP System.
9 All specifications are subject to change without notice.
42 Aero Camino, Goleta, CA 93117
Tel (805) 685-0066 | Fax (805) 685-0067
www.biopac.com

Other manuals for BIOPAC Systems, Inc. MP150

Question and Answer IconNeed help?

Do you have a question about the BIOPAC Systems, Inc. MP150 and is the answer not in the manual?

BIOPAC Systems, Inc. MP150 Specifications

General IconGeneral
TypeData Acquisition System
Input Range±10 V
Resolution16-bit
Common Mode Rejection Ratio>100 dB
Channels16
Sampling RateUp to 400 kHz aggregate
Communication InterfaceUSB
Weight5 lbs

Summary

Chapter 1 MP Systems

MP150 STARTER SYSTEM

Details the components included in the MP150 starter system.

MP System Specifications — for MP150 and MP100

Chapter 2 Interface Modules

UIM100C UNIVERSAL INTERFACE MODULE

Describes the UIM100C as the interface between MP150/100 and external devices.

HLT100C HIGH LEVEL TRANSDUCER INTERFACE MODULE

TSD109 Calibration

Software Setup

Step-by-step guide for setting up software for TSD109 calibration.

Chapter 3 General Purpose Transducer Amplifier Module

DA100C – DIFFERENTIAL AMPLIFIER MODULE

Describes the DA100C as a single-channel differential amplifier for various transducers.

DA100C Calibration

C. Transducer Calibration if applying physical variable

Steps for calibrating the transducer using the physical variable.

TSD107B HIGH-FLOW PNEUMOTACH TRANSDUCER

Hardware Setup

Provides instructions for setting up the TSD107B hardware.

TSD117 Calibration

Calibration Procedure Options

Options for calibrating the TSD117 transducer without a syringe.

TSD130 SERIES GONIOMETERS & TORSIOMETERS

Chapter 4 Biopotential / Transducer Modules

100C series modules

Describes the features and capabilities of the 100C series modules.

ECG100C – ELECTROCARDIOGRAM AMPLIFIER MODULE

DTU100 DIGITAL TRIGGER UNIT

DTU100 CONTROLS

Details the controls and functions of the DTU100 Digital Trigger Unit.

EEG100C – ELECTROENCEPHALOGRAM AMPLIFIER MODULE

EGG100C – ELECTROGASTROGRAM AMPLIFIER MODULE

EMG100C – ELECTROMYOGRAM AMPLIFIER MODULE

EOG100C – ELECTROOCULOGRAM AMPLIFIER MODULE

ERS100C – EVOKED RESPONSE AMPLIFIER MODULE

GSR100C – ELECTRODERMAL ACTIVITY AMPLIFIER MODULE

PPG100C – PHOTOPLETHYSMOGRAM AMPLIFIER MODULE

RSP100C – RESPIRATION PNEUMOGRAM AMPLIFIER MODULE

SKT100C – SKIN TEMPERATURE AMPLIFIER MODULE

SKT100C Calibration

Instructions for setting up SKT100C for temperature measurements.

Chapter 5 Gas Concentration Measurement Modules

O2100C and CO2100C

Introduces the O2100C and CO2100C gas analyzers.

Calibration

Gas Sampling Setup

Steps for setting up the gas sampling system for calibration.

O2100C Oxygen Measurement Module

CO2100C Carbon Dioxide Measurement Module

GASSYS2-RA/B CO2 & O2 Gas Analysis System

Chapter 6 Specialty Modules

OXY100C Pulse Oximeter Module

Describes the OXY100C for measuring blood oxygen saturation and pulse rate.

EBI100C Electrical Bio-Impedance Amplifier

NICO100C

MCE100C Micro-electrode Amplifier

LDF100C Laser Doppler Flowmetry Module

TROUBLESHOOTING

POSSIBLE ERRORS & SUGGESTIONS

NIBP100A Noninvasive Blood Pressure Measurement System

FOTS100 Fiber Optic Temperature System

ITBS100 Integrated Tissue Bath

MPMS100A-1/MPMS100A-2 Micro Pressure Measurement System

MPMS100A Control Unit

Describes the control unit for the micro pressure measurement system.

Chapter 7 Stimulation Options

STM100C Stimulator module

Describes the STM100C as a single channel stimulation amplifier.

STM200 Stimulator

STMISOL Linear Isolated Stimulator

IMPORTANT SAFETY NOTES!

Highlights critical safety information for stimulus isolation units.

STMISOC Constant voltage or constant current stimulus isolation adapter

STP100W Stimulus Presentation System (SuperLab™)

Chapter 8 Remote Monitoring

TEL100C Remote Monitoring System

Describes the TEL100C system for remote monitoring.

Chapter 9 Power & Cables

BAT100 Rechargeable Battery Pack

BAT100 Battery Pack Specifications

Lists the specifications for the BAT100 rechargeable battery pack.

MEC Series Module Extension Cables

IMPORTANT SAFETY NOTES

Critical safety guidelines for MEC series cables.

Chapter 10 Virtual Reality

Head Mounted Displays

Describes the HMD1 and HMD2 head-mounted displays.

HDS100 Haptic Delivery System

HDS100 Specifications

Lists the specifications for the HDS100 haptic delivery system.

SDS100 Scent Delivery System

SDS100 Specifications

Lists the specifications for the SDS100 scent delivery system.

Chapter 11 Eye Tracking

Eye Tracking System Specifications

Details the specifications for the eye tracking system.