Transmitter
PCB Transmitter
Terminals
Battery 1 CR2032
Battery 2 CR2032
LED (activation)
DIP - Switch
Push button
Antenna
Receiver
Receiver printed circuit board
Terminals
LED 1 (system readiness,
channel ➔ Sender 1)
LED 2 (system readiness,
channel ➔ Sender 2)
Key
DIP switch
LED 3 (programming mode)
Buzzer
Antenna
1
2
1
0
10
Warning: Switch off the operating voltage before working on the system. Only trained, qualified personnel may perform installation and startup.
The unit may only be opened and repaired by Bircher Reglomat employees. The switching unit may only be used to protect against dangers at crushing
and automatic industrial doors (designated use). Applicable regulations on industrial door safety must be complied with. Always consider the safety
functions of your application as a whole, never just in relation to one individual section of the system. The installer is responsible for carrying out a
risk assessment and installing the industrial door system correctly. Notice: It’s recommended to change the battery every year.
Startup
2
Installing the transmitter (cable outlet at bottom)
2.1
R
e
c
o
m
m
e
n
d
e
d
s
t
a
r
t
-
u
p
s
e
q
u
e
n
c
e
:
M
o
u
n
t
i
n
g
s
e
n
s
o
r
/
I
n
i
t
i
a
l
i
s
a
t
i
o
n
/
C
o
n
n
e
c
t
s
e
n
s
o
r
Notice:
For technical reasons relating to radio trans-
mission, the transmitter and receiver should
not be installed on the same surface if possi-
ble.
The distance between transmitter and receiver
as well as between the transmitters among
themselves has to be at least 1m.
Tip:
If the distance between the transmitter and
receiver is relatively large, we recommend
programming the transmitters on the receiver
before installation.Transmitters can be learned
in with or without a connected detector /
switch.
175 mm
Transmitter: insert batteries
2.2
1. Remove the PCB from the housing.
2. Insert the enclosed batteries (type CR2032).
Important:
Insert battery 1 first and then battery 2.
Unless this order is observed, correct function
is not guaranteed.
Installing the receiver (cable outlet at bottom)
2.3
Cable diameter:
3 – 6.5 mm
Connecting the receiver
2.4
1
See 3.1 See 3.1
1: Wire up thepowersupply to the controller 2: Wire up the output to the controller
Note correct polarity for DC!
Input type
sensor/safety edge
Input type
Contact NC
Input type
Contact NO
The system is not
fused.We recommend
protecting the supply
with a fuse of min.
100 mA, max. 250 mA.
Controller
Input
Sensor 8.2 kOhm
Input
NC
Input
NO
see 3.3
Drilling template
2 2