PrimeTec B / PrimeScan B
Cable
+
+
+
3 m
+
1 2
1 2
1 21 2
1 2
LCD
1 2 1
Radar AIR
BBC Bircher Smart Access, BBC Bircher AG, Wiesengasse 20, CH-8222 Beringen, www.bircher.com 1 / 2
PrimeTec B
PrimeScan B
Short guide
ENGLISH
299140D
01/19
PrimeScan B
PrimeTec B
Please mind the original manual!
Electrical connections
Conguration using programming buttons (Operator buttons)
Presetting
Automatic Cong. mode Choose Choose Funct./Parameter Back to choice Back to autom.
Operator buttons
red (Function)
black (Value)
A: Automatic mode
t: Test active
Radar
output on
AIR
output on
Press shortly both
buttons
simultaneously
Red button:
switch
between Radar, AIR
and general
Black button:
choose
Red button:
Choose
parameter
Black button:
Choose value of the
parameter
Press both
buttons
Press both
buttons
Switches to automatic
mode (A) automatically
after 1 min
General
Radar functions (PrimeTec)
OPERATION OF THE BUTTONS
1
DESCRIPTION
LCD
Field size
1 1 – 5
1
= Smallest radar eld, ......., * = Medium radar eld, ......, = Largest radar eld
Direction recognition
2 1 – 2
1
= both directions
* = forward
Cross Trac Optimisation CTO
(Cross Trafc Optimisation)
4 1 – 2
1
* = Off
= On (recommended only at narrow eld)
Door lter
6 1 – 2
1
* = Filter off
= Door and interference lter on (EMV ows, e.g. uorescence tube)
Radar output
7 1 – 2
1
* = active
= passive
The Slow Motion Detection (SMD) is a factory setting. The SMD recognises slow motions after the detecor has been activated.
AIR functions
(PrimeTec / PrimeScan)
OPERATION OF THE BUTTONS
1
DESCRIPTION
Function Value
LCD
Set sensitivity
1 1 – 5
2
= high sensitivity (acc. to EN 16005 ≤ 3m, only indoors)
= medium sensitivity (acc. to EN 16005 ≤ 3m) = low sensitivity (acc. to EN 16005 ≤ 2.3m)
* = normal sensitivity (acc. to EN 16005 ≤ 2.6m) = very low sensitivity
Set teach-in time
2 1 – 5
2
= 10 s * = 30 s (acc. to EN 16005) = 60 s (acc. to DIN 18650 + AS 5007)
= 180 s = 15 min
AIR output contact logic
3 1 – 4
2
= active (NO)
no detection
contact open
* = passiv (NC)
no detection
contact closed
Series connection
Settings
Master Slave
Master Slave
Wiring: See series connection diagram:
reglomat.bircher.com/en/
products-technologies/primefamily-b
AIR output
4 1 – 2
2
* = On
= Off (AIR is going to be reactivated automatically after 15 minutes)
General functions
(PrimeTec / PrimeScan)
 
OPERATION OF THE BUTTONS
1
DESCRIPTION
Function Value
LCD
Reset
+
Press both buttons 8
seconds
Initialisaiton and teaching of the background
Presetting
(After presetting and leaving
cong. a reset will be done automatically)
1
1 – 8
Press value for
1 second
to change the
presetting
1
2
= Standard, = footpath, = home for the aged, = wind screen,
= high door, = narrow door, = wide door,
= factory settings
For all values set,
parameter 0 is displayed
Combined outputs
activated / not activated
2 1 – 2
1
2
= activated (radar and AIR actuate the radar output)
* = not activated
AIR-frequency
(In the case of
overlapping AIR elds consider the
addressing order: odd nr. 1 even nr. 2
odd nr. 3)
3 1 – 6
2
1
* = Frequency 1 = Frequency 3 = Frequency 5
= Frequency 2 = Frequency 4 = Frequency 6
In the case of overlapping AIR elds consider the frequency order: odd number even number odd number
1
Press both buttons shortly for conguration mode / * Factory setting
Standard Foot path Home for the aged Wind screen High door Narrow door Wide door Factory settings
Radar eld size
3 3 3 2 4 2 5 3
Field geometry
2
wide narrow wide wide wide narrow wide wide
Cross Trac Optimisation
1 2 1 1 1 1 1 1
2
Field geometry has to be set manually
Power Supply
1 white
white
2 brown
brown
3 green
green
4 yellow
6 pink
pink
5 grey grey
yellow
7 blue
blue
8 red
red
Radar output
Test
11.5 – 32 VDC
Controller
Radar
Test
AIR
AIR output
Question and Answer IconNeed help?

Do you have a question about the Bircher PrimeTec B and is the answer not in the manual?

Summary

Electrical Connections

Power Supply and Output Connections

Details the wiring for power supply, radar output, test signal, and AIR output.

Configuration and Operation Modes

Operator Button Functions

Explains the use of operator buttons for automatic, config, and selection modes.

General Button Operations

Describes general button use for Radar, AIR, and general settings selection.

Radar and AIR Function Settings

Radar Functions Configuration

Covers settings for field size, direction, Cross Traffic Optimisation, door filter, and radar output.

AIR Functions Configuration

Details settings for AIR sensitivity, teach-in time, output contact logic, and output activation.

General Functions and Presetting

Device Reset and Presetting

Instructions for device reset and overview of presetting functions.

Combined Outputs and AIR Frequency

Settings for combined outputs and AIR frequency in overlapping fields.

Specific Presetting Options

Presets for radar field size, geometry, and Cross Traffic Optimisation.

Initialisation and Mechanical Fine Tuning

Initialisation Procedure

Steps for initialising the door system and LED indicators.

Radar Field Mechanical Adjustments

Manual settings for inclination and pivot angles of the radar field.

AIR Field Mechanical Adjustments

Settings for AIR field inclination and width adjustment.

Bircher PrimeTec B Specifications

General IconGeneral
Detection ModeMotion and presence detection
Operating Temperature-20°C to +55°C
Protection ClassIP54
TechnologyMicrowave
Mounting HeightUp to 4 m
Supply Voltage12-24 VAC/VDC
Detection AreaAdjustable
Housing MaterialABS
Power Supply12-24 VAC/VDC
Weight150 g