PrimeTec B / PrimeScan B
Cable
+
+
+
3 m
+
1 2
1 2
1 21 2
1 2
LCD
1 2 1
Radar AIR
BBC Bircher Smart Access, BBC Bircher AG, Wiesengasse 20, CH-8222 Beringen, www.bircher.com 1 / 2
PrimeTec B
PrimeScan B
Short guide
ENGLISH
299140D
01/19
PrimeScan B
PrimeTec B
Please mind the original manual!
Electrical connections
Conguration using programming buttons (Operator buttons)
Presetting
Automatic Cong. mode Choose Choose Funct./Parameter Back to choice Back to autom.
Operator buttons
red (Function)
black (Value)
A: Automatic mode
t: Test active
Radar
output on
AIR
output on
Press shortly both
buttons
simultaneously
Red button:
switch
between Radar, AIR
and general
Black button:
choose
Red button:
Choose
parameter
Black button:
Choose value of the
parameter
Press both
buttons
Press both
buttons
Switches to automatic
mode (A) automatically
after 1 min
General
Radar functions (PrimeTec)
OPERATION OF THE BUTTONS
1
DESCRIPTION
LCD
Field size
1 1 – 5
1
= Smallest radar eld, ......., * = Medium radar eld, ......, = Largest radar eld
Direction recognition
2 1 – 2
1
= both directions
* = forward
Cross Trac Optimisation CTO
(Cross Trafc Optimisation)
4 1 – 2
1
* = Off
= On (recommended only at narrow eld)
Door lter
6 1 – 2
1
* = Filter off
= Door and interference lter on (EMV ows, e.g. uorescence tube)
Radar output
7 1 – 2
1
* = active
= passive
The Slow Motion Detection (SMD) is a factory setting. The SMD recognises slow motions after the detecor has been activated.
AIR functions
(PrimeTec / PrimeScan)
OPERATION OF THE BUTTONS
1
DESCRIPTION
Function Value
LCD
Set sensitivity
1 1 – 5
2
= high sensitivity (acc. to EN 16005 ≤ 3m, only indoors)
= medium sensitivity (acc. to EN 16005 ≤ 3m) = low sensitivity (acc. to EN 16005 ≤ 2.3m)
* = normal sensitivity (acc. to EN 16005 ≤ 2.6m) = very low sensitivity
Set teach-in time
2 1 – 5
2
= 10 s * = 30 s (acc. to EN 16005) = 60 s (acc. to DIN 18650 + AS 5007)
= 180 s = 15 min
AIR output contact logic
3 1 – 4
2
= active (NO)
no detection
contact open
* = passiv (NC)
no detection
contact closed
Series connection
Settings
Master Slave
Master Slave
Wiring: See series connection diagram:
reglomat.bircher.com/en/
products-technologies/primefamily-b
AIR output
4 1 – 2
2
* = On
= Off (AIR is going to be reactivated automatically after 15 minutes)
General functions
(PrimeTec / PrimeScan)
 
OPERATION OF THE BUTTONS
1
DESCRIPTION
Function Value
LCD
Reset
+
Press both buttons 8
seconds
Initialisaiton and teaching of the background
Presetting
(After presetting and leaving
cong. a reset will be done automatically)
1
1 – 8
Press value for
1 second
to change the
presetting
1
2
= Standard, = footpath, = home for the aged, = wind screen,
= high door, = narrow door, = wide door,
= factory settings
For all values set,
parameter 0 is displayed
Combined outputs
activated / not activated
2 1 – 2
1
2
= activated (radar and AIR actuate the radar output)
* = not activated
AIR-frequency
(In the case of
overlapping AIR elds consider the
addressing order: odd nr. 1 even nr. 2
odd nr. 3)
3 1 – 6
2
1
* = Frequency 1 = Frequency 3 = Frequency 5
= Frequency 2 = Frequency 4 = Frequency 6
In the case of overlapping AIR elds consider the frequency order: odd number even number odd number
1
Press both buttons shortly for conguration mode / * Factory setting
Standard Foot path Home for the aged Wind screen High door Narrow door Wide door Factory settings
Radar eld size
3 3 3 2 4 2 5 3
Field geometry
2
wide narrow wide wide wide narrow wide wide
Cross Trac Optimisation
1 2 1 1 1 1 1 1
2
Field geometry has to be set manually
Power Supply
1 white
white
2 brown
brown
3 green
green
4 yellow
6 pink
pink
5 grey grey
yellow
7 blue
blue
8 red
red
Radar output
Test
11.5 – 32 VDC
Controller
Radar
Test
AIR
AIR output

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bircher PrimeTec B and is the answer not in the manual?

Bircher PrimeTec B Specifications

General IconGeneral
Detection ModeMotion and presence detection
Operating Temperature-20°C to +55°C
Protection ClassIP54
TechnologyMicrowave
Mounting HeightUp to 4 m
Supply Voltage12-24 VAC/VDC
Detection AreaAdjustable
Housing MaterialABS
Power Supply12-24 VAC/VDC
Weight150 g