SRP-E300/302
Ver. 1.01 BIXOLON
- 38 -
ESC V
Function:
Turn 90°clockwise rotation mode on/off
Code:
ASCII
ESC
V
n
Hex
1B
56
n
Decimal
27
86
n
Range:
0 ≤ n ≤ 2, 48 ≤ n ≤ 50
Default:
n = 0
Description:
This command turns 90° clockwise rotation mode on/off in standard mode according to the value of n as following
When the value of n is equal to 0 or 48, 90°clockwise rotation mode is turned off.
When the value of n is equal to 1, 2, 48, or 50, 90°clockwise rotation mode is turned on.
Remarks:
In underline mode, the underline printing for 90° clockwise rotated characters does not work, and the relationship
between vertical and horizontal directions is reversed.
The 90° clockwise rotation mode is not effective in page mode.
If set in page mode, the 90° clockwise rotation mode has effect after the printer returns to standard mode.
The setting of this command remains effective until ESC !, ESC @, printer reset or power cycling is executed.
Differences:
None

Other manuals for BIXOLON SRP-E302