<Function 69> GS ( L pL pH m fn kc1 kc2 x y (fn=69)
Code:
ASCII
GS
(
L
pL
pH
m
fn
kc1
kc2
x
y
Hex
1D
28
4C
pL
pH
m
fn
kc1
kc2
x
y
Decimal
29
40
76
pL
pH
m
fn
kc1
kc2
x
y
Range:
(pL + pH x 256) = 6 (pL=6, pH=0)
m=48, fn=69
32 ≤ kc1 ≤ 126
32 ≤ kc2 ≤ 126
x=1, 2
y=1, 2
Default:
None
Description:
Prints the NV graphics data defined by the codes kc1 and kc2.
The graphics data is enlarged by x and y in the horizontal and vertical directions.
Remarks:
This command prints the NV graphics data defined by Function 67.
In page mode, this command is not effective.
NV graphics data beyond the print area for one line is not printed.
Differences:
None