SRP-E300/302
Ver. 1.01 BIXOLON
- 78 -
<Function 067> GS ( k pL pH cn fn n (fn=67)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
30
43
n
Decimal
29
40
107
3
0
48
67
n
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=67
1 ≤ n ≤ 4
Default:
n = 3
Description:
This command sets the width of the module of PDF417 symbol to n dots.
Remarks:
Settings of this command affect the processing of Functions 081.
The setting unit for printer models varies.
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences:
Setting unit(1 dot):
SRP-E300 : 0.141(1/180 inch)
SRP-E302 : 0.125(1/203 inch)