■ In standard mode, this command is available only when printer is at the beginning of a line or the printer buffer is
empty.
■ A symbol exceeding the printing area in size can not be printed.
■ Printing operation is not processed under the following conditions:
• There is no data (Function 080 is not processed).
• If [(number of columns x number of rows) < number of code word] when automatic processing is specified for
number of columns and number of rows.
• Number of code word exceeds 928 in the data area.
■ The following data is added automatically by the encode processing:
• Start pattern and stop pattern.
• Indicator code word of left and right.
• The descriptor of symbol length (the first code word in the data area).
• The error correction code word calculated by modulus 929.
• Pad codeword.