<Function 165> GS ( k pL pH cn fn n1 n2 (fn=65)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
n1
n2
Hex
1D
28
6B
04
00
31
41
n1
n2
Decimal
29
40
107
4
0
49
65
n1
n2
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=49
fn=65
n1 = 49, 50
n2 =0
Default:
n1 = 50, n2 = 0
Description:
This command sets the QR Code model as follows:
n1
Function
49
Model 1
50
Model 2
Remarks:
The setting of this command affects <Function 181>.
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.