4 -- 25
4.3.11 Bar code types
-- EAN13 code -- PDF417
-- EAN Add on 2--digit -- PDF417 with AI
-- EAN Add on 5--digit -- RSS14
-- EAN8 code -- RSS expanded
-- EAN128 code -- Composite code
-- Code 128 -- UPC--A--Code
-- Code 2/5 int. -- ITF code
-- Code 39 -- EAN--D3 code
-- Data Matrix -- EPC96
-- Maxi Code
4.3.12 Label output
Remove printed label from labeler and affix to the package.
Remove cut labels from Linerless label printer and affix to the package.
4.3.13 Load receptor for connection to the GLP
The following load receptors with different maximum capacities and scale inter-
vals may be connected to GLP labeler.
Type Load
receptor
Dimen-
sions
WxDxH
(mm)
Dimen-
sions
WxDxH
(”)
Weighing
range
Scale
interval
Reso-
lution
Tare
range
0602
Type
335 x 13,18 x 6 kg 2 g 3 000 6 kg
18A--M
260 x 10,23 x 15 lb 0,01 lb 1 500 15 lb
119--130 4,6--5,1 (UK only) 1/8 oz 1 920 15 lb
1505 15 kg 5 g 3 000 15 kg
30 lb 0,01 lb 3 000 30 lb
0602
Type
335 x 13,18 x 6 kg 2 g 3 000 6 kg
20A--M
260 x 10,23 x 15 lb 0,01 lb 1 500 15 lb
85--100
3,3--3,9
(UK only) 1/8 oz 1 920 15 lb
1505 15 kg 5 g 3 000 15 kg
30 lb 0,01 lb 3
000
30 lb
3010
Type
500 x 19,68 x 30 kg 10 g 3 000 30 kg
150A--M
400 x 15,74 x 60 lb 0,02 lb 3 000 60 lb
6020
92--98 3,6--3,8 60 kg 20 g 3 000 60 kg
800 x 31,49 x 150 lb 0,05 lb 3 000 150 lb
0150
600 x 23,62 x 150 kg 50 g 3 000 150 kg
115--130 4,5--5,1 300 lb 0,1 lb 3 000 300 lb
Type designations
Type xxA--M, e. g. 150A--M for connection to price labeler GLP (M = Minibus).
4.3