Operating instructions GLP
5 -- 23
6.562.98.5.01.18
List 4: identical articles, weight total, 3--column
After labeling of an article item, the accumulated weight total is printed on the list
in two columns together with the consecutive total label No. *1 simultaneously
with total label *1 or total label *2. Consequently, the operating mode ”with total
1 numerator” must be set at mode level 5. If ”total” labels *2 are printed, the total
number and the total weight will be printed subsequent to item list printing.
List header:
The list header is automatically printed after calling the list, on a PLU change and
a page feed.
The text stored in the text field 1 (e. g. the company logo), the article description
stored in text field 2, the PLU number and the best before/sell--by date are printed
in the list header.
Page feed:
A page feed takes place after each full page, after a PLU change and after printout
of total 2.
Page numerator:
The page numerator reading at the end of each page is increased every time a
new page is commenced and is reset on call of a different article.
List example:
BIZERBA
Contents of text field 1
PLU number
Article: Rumpsteak
Article no.: 123
Contents of text field 2
Date 2Date: 25.4.96
Items Weight Items Weight Items Weight
Total pieces:
Total weight:
5