BK Medical Flex Focus 500 Service Manual

Default Icon
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Service Manual
Diagnostic Ultrasound System
Flex Focus 200, Flex Focus 200 Surgery,
Flex Focus 400, Flex Focus 400 Anesthesia,
Flex Focus 500, Flex Focus 700, Flex Focus 800

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the BK Medical Flex Focus 500 and is the answer not in the manual?

BK Medical Flex Focus 500 Specifications

General IconGeneral
BrandBK Medical
ModelFlex Focus 500
CategoryDiagnostic Equipment
LanguageEnglish

Summary

General Information

Safety Aspects

Details on safety aspects for the 1202 System.

Terms and Symbols Used

Defines terms and safety symbols used in the manual.

WARNINGS and CAUTIONS

Provides critical warnings and cautions for safe operation and maintenance.

Modules

Details the different modules and their part numbers.

Electrical Safety Test

Details testers and adapters required for electrical safety testing.

Checking Procedure

Before Power Up

Ensures correct mains connection before powering on the system.

Troubleshooting

Trouble shoot Specific Problems (Hints)

Provides common problem symptoms and initial troubleshooting steps.

Service Mode

Instructions on entering and using the service mode.

Enter Service Mode

Detailed steps to enter the scanner's service mode.

How to set scanner to Normal (console) Mode - exit Service Mode

Procedure to exit service mode and return to normal console operation.

Changing Core board/Core board Assembly

Procedure for replacing the core board and reprogramming serial numbers.

Changing Flat Panel Assembly ZN0051

Procedure for replacing the flat panel and transferring calibration data.

Installing a XP Embedded Image

Overview of installing the XP Embedded image, including BIOS access.

BIOS access

Steps to access the system's BIOS setup menu.

Dicom

Configuration for DICOM features, network setup, and AE Title.

How to recover from a crashed main database

Steps to recover the main database after corruption.

How to recover patient database from a crashed system

Procedure to recover the patient database and its tool.

Patient Database Recovery tool

Details on using the Patient Database Recovery tool.

Adjustment Procedure

Touch Screen Adjustment and Calibration

Procedure for adjusting and calibrating the touch screen.

Mechanical parts

Dismantling and Reassemble Procedures

Step-by-step procedures for disassembling and reassembling the scanner.

Remove the Front Frame

Procedure for removing the front frame of the scanner.

Undock the Scanner unit

Steps to safely disconnect the scanner unit from its dock.

Remove the Flat Panel

Procedure for removing the flat panel display.

Remove the electronic assembly from the scanner

Procedure to remove the main electronic assembly from the scanner.

Removing the Hard disk

Procedure for removing the system's hard disk drive.

Removing the Highspeed cable

Procedure for removing the high-speed data cable.

Removing the DVD

Procedure for removing the DVD drive.

Removing the keyboard (from Keyboard Dock)

Procedure for removing the keyboard from the keyboard dock.

Removing the Transducer holder (from Keyboard Dock)

Procedure for removing the transducer holder.

Removing the Power Supply (from Keyboard Dock)

Procedure for removing the power supply from the keyboard dock.

Removing the Track Pad (from Touch Dock)

Procedure for removing the track pad from the touch dock.

Exploded view / Part list

Provides an exploded diagram and a list of all parts.

Preventative Maintenance

Related product manuals