61
[SOURce:]LIST:COUNt
This command sets the number of times that the list is executed before it is completed. The command
accepts parameters in the range 1 through 65536, but 65536 is interpreted as infinity.
Command Syntax
[SOURce:]LIST:COUNt <NRf+>
Parameters
1 to 65536
Examples
LIST:COUN 3
Query Syntax
[SOURce:]LIST:COUNt?
Returned Parameters
<NR3>
Related Commands
LIST:STEP
[SOURce:]LIST:STEP
This command sets the total number of steps in the list.
Command Syntax
[SOURce:]LIST:STEP <NRf+>
Parameters
2 to 84
Examples
LIST:STEP 5
Query Syntax
[SOURce:]LIST:STEP?
Returned Parameters
<NR3>
Related Commands
LIST:LEV
[SOURce:]LIST:LEVel?
This command specifies the level value
Command Syntax
[SOURce:]LIST:LEVel <NR1>, <NRf>
Parameters
1 to max. rated current.
Unit
None, None
Examples
LIST:LEV 1, 10 LIST:LEV 2, 15.2
Query Syntax
[SOURce:]LIST:LEVel? <NR1>
<NR1> is step number
Returned Parameters
<NR3>