INSTRUCTIONS FOR THE INSTALLER
18






18B
GAS CONNECTION
This appliance shall be installed only by
authorised personnel and in accordance with the
manufacturer’s installation instructions, local gas
ſVVKPITGIWNCVKQPUOWPKEKRCNDWKNFKPIEQFGUYCVGT
supply regulations, electrical wiring regulations,
AS 5601 - Gas Installations and any other
statutory regulations.
The appliance is adjusted to work with the gas
indicated on the label which is applied on the
glass-window of the oven door and on the cooker
packing.
Installation for Natural gas
%QPPGEVTGIWNCVQT$VQſVVKPI#YJKEJKUVJGP
ſVVGFVQGNDQY('PUWTGCTTQYQPTGIWNCVQT
point in the direction shown. Fitting (D) to be
UWRRNKGFD[KPUVCNNGTſI$#FLWUVTGIWNCVQT
to give test-point pressure given on data label on
<TECHNICAL FEATURES> paragraph, with one
large or one medium burner alight at maximum.
2QUKVKQPQH4GIWNCVQTſI
The stove must be installed on legs which come
YKVJVJGRTQFWEVCICURKRGDGVYGGPſVVKPI
(A) and (B) will allow location of the regulator
(B) underneath the stove for adjustment and
maintenance.
Installation for Propane Gas ſI#
Connect by using a copper pipe starting, from the
VJTGCFGFſVVKPIQHGNDQY(
+PUVCNNCVKQPWUKPIƀGZKDNGEQPPGEVKQP
As an option, the cooker may be installed with a
ƀGZKDNGEQPPGEVKQPJQUGYJKEJEQORNKGUYKVJ#5
0<5#)##RRTQXGFOO+&ENCUU$QT
D, Minimum 1000 mm - Maximum 1200 mm, as an
alternative connection.
All cookers offer left or right hand connection.
6JGOCPKHQNFJCUCƀCVƀCKTQXGTYJKEJKU
inserted a screw nut male ½ICUſI$
An isolating tap and pressure regulator must
DGſZGFVQVJGTGCTYCNNCPFVJGƀGZKDNGRKRG
attached by means of a union connector.
The gas connection and isolating tap must be
accessible to a service person or inspector.
The hose assembly must be installed in
accordance with AS5601 for a high level
connection. The hose should not be subjected
0QVG9JGPVJGTGIWNCVQTKUſVVGFCVVJGTGCTQH
the cooker at least 60 mm clearance is required.
to abrasion, kinking or permanent deformation
and should be able to be inspected along its
entire length. Unions compatible with the hose
ſVVKPIUOWUVDGWUGFCPFEQPPGEVKQPUVGUVGF
HQTICUNGCMU6JGſZGFEQPUWOGTRKRKPI
outlet should be at approximately the same
height as the cooker connection point, pointing
downwards.
6JGJQUGUJQWNFDGENGCTQHVJGƀQQTYJGPVJG
cooker is in the installed position. The anti-tilting
chain supplied should be anchored to the lower
JQQMſZGFVQVJGYCNNUQVJCVVJGEJCKPRTGXGPVU
strain
on the hose connections when the cooke
r
is
pulled fo
r
wa
r
d.
18A








