Other malfunctions
Malfunctions Possible causes Malfunction correction
No response
to operation at
the mixer tap
(blue LED)
Faulty com-
munication
to the mixer
tap
- Faulty operation
- Incorrect signal
- Unplug the signal cable from the
cooling and carbonisation unit and
plug it in again
Faulty images
on the display
Faulty
communi-
cation to the
display
- Faulty operation
- Incorrect signal
- Disconnect the power supply and
reconnect it
Mixer tap is dripping from the
soda outlet
- Calibrate the system (see p. 45 + 51)
- Check the soda pipe
- Set the soda pipe length correctly
(contact Customer Service)
Only CO₂ is coming out of the
soda outlet
Air or CO₂ in the system
because:
- Filter not inserted
correctly
- Angle valve closed
- Water supply disrupted
- Filter reinstalled
- Evacuate air from the system (see p. 57)
Check that the filter has been installed
correctly (see p. 50)
- Check water inlet
Spray from the soda tap spitting/
uneven soda spray
The soda spray is too weak - CO₂ cylinder empty - Evacuate air from the system (see p. 57)
- Change CO₂ cylinder
The volumes dispensed do not
match the pre-selected volumes
- CO
2
cylinder not
inserted correctly
- CO
2
cylinder empty
- Calibration not yet
performed
- Check CO
2
cylinder fill level
- Check that the CO
2
cylinder is positioned
correctly. If necessary, remove the CO
2
bottle and reinsert it. When inserting
the cylinder, screw it in as far as the
mechanical stop. Then tighten with
another 1/4 turn so that the cylinder is
firmly in place.
- Perform system calibration
(see p. 45 + 51)
Malfunctions
56