MIDDLE DRAINAGE
When unit running in Dry mode, you can choose the way below to drainage.
1. Unplug the unit from the power source.
2. Remove the drain plug(fig A). While doing this operation some residual water may spill
so please have a pan to collect the water.
3. Connect the drain hose (1/2" or 12.7mm, maybe not supplied ). (fig B)
4. The water can be continuously drained through the hose into a floor drain or bucket.
5. Turn on the unit.
NOTE
Please be sure that the height of and section of the drain hose should not be higher than
that of the drain outlet, or the water tank may not be drained. Please see following fig.
Garden hose or
drainage hose
Drain cap