chamber.
5. When the cool water flowing out through the overflow tube or the machine doesn’t
heating, please immediately stop using it and check whether the magnetic value is
block or the heating element is damaged, then clean it or replace it.
6. The waterproofing grade of this machine is “IPXO”, when cleaning its case, please
first cut off the power, then wipe it with cloth. Corrosive cleanser can’t be used, and
don’t flush it directly or soak it.
7. If the power wire is damaged and need to replace, please first cut off the main power,
and replace with YZW Type、heat-resistant and anti-corrosion power wire, any
other power wire are forbidden.
Ⅸ. Specification
Model Water Pressure Power Voltage Frequency Capacity Productivity Faucet
BC110-
0.2-
2500W ~220-
50Hz 10L 35L/h 1
Ⅹ.Error code and trouble shooting
Drinking water thermoprobe failure
To check if its connection is loosen
Heating thermoprobe failure
To clean up the scail attach on it and
check if its connection is loosen
Inflowing failure (the water fill in more than
45 minutes
1. To check whether the water
resource is under normal supply.
2. To check the magnetic value.
Replace the heating element
1. To check whether the water
resource is under normal supply.
2.
To check the magnetic value,
replace it if needed.
3. To check whether the connection of
every thermo probes is fixed.
The timing
indicator
flashing
If there are some circuit failure appear in the
timer, the timing function would be invalid
To replace a new display board or
circuit board.