or “Minus” button to set your needed time, then exit to save the data; repeat the
procedure to set up another data.
3) Setting “Timer Off”, you can contrast with the sheet above when operating.
Procedure: 1.press “Set” button to switch between “Hour”/”Minute”; 2.press “Plus”
or “Minus” button to set your needed time, then exit to save the data; repeat the
procedure to set up another data.
4) After finishing these three procedure before, press “Set” button to switch to OFF
status, long press the “Switch” button for 2 seconds, the machine start working,
then press the “Timing” button, the timing indicator light on, means the timing
function is effective.
Ⅶ. Peri odi c i nspection
Inspection item Content Standard
Connection To check whether the plug or power line are hot or loosen. Once a
day
Drain outlet To check whether the outlet is block Once a
month
Chamber cleaning At least once a season, both chamber and surface should be cleaned, can use a
nylon bundle to clean off the scale on the thermo probe and heating element and
loosen the nut of the drain outlet to drain out the waste water.
Once a
season
Ⅷ. Maintenance
1. The machine should have regular checking, if not using during holiday and a long
time, please turn off the power and water, and drain out all the water in the chamber
to avoid the burn-in of the parts and extend their service life.
2. Pay attention on cleaning the thermo probes and heating element, to avoid scaling
influence the working system. Also the cleanser which sales in market can be used
for cleaning, please combine with the actual circumstances to choose it. We suggest
to clean the machine once a season. (Recommend to be done by a skilled technician).
3. Open the top cover of the chamber, after cleaning or maintenance, it need to check
whether the seal ring is damaged and fixed, then fasten it again, replace the top
cover and try one or two heating cycle to ensure there is no steam leakage, or it may
influence the using safety and damage the machine. (Recommend to be done by a
skilled technician).
4. There is a drain outlet at the back on the machine, please drain out the water
regularly according to actual circumstances. All the power and water should be cut
off when operating, and please wait for a minute to cool down the water before
drain then out. Don’t knocking the machine or using sharp metal tools to clean