4
- All Other Markets:
NOTE:
(*) Measure burner operating pressure at Lower Test Point (Out) on the gas control
valve, with both burners operating at 'High Flame' setting.
(**) TOWN GAS Option is only available with specific ex-factory built Town Gas
models, which can also be converted to any other gas. Standard models can only be
converted between Nat. Gas, LP Gas and Butane, but not Town Gas.
Refer to ‘Gas Conversion and Specifications' section of this manual for further details.
Input Rating (N.H.G.C.) 90 MJ/hr 90 MJ/hr
Supply Pressure
Non-CE 1.13 - 2.0 kPa 0.75 - 1.5 kPa
CE 25 mbar N/A
Burner Operating Pressure (*) 0.98 kPa 0.5 kPa
Gas Connection ¾” BSP Male
Input Rating (N.H.G.C.) 90 MJ/hr 90 MJ/hr
Supply Pressure
Non-CE 2.75 - 3.0 kPa 2.75 - 3.0 kPa
CE 37 mbar 37 mbar
Burner Operating Pressure (*) 2.5 kPa 2.5 kPa
Gas Connection ¾” BSP Male