Model | A-100N |
---|---|
Adjustment | Manual |
Max Working Pressure | 100 PSI |
Flow Rate | 0.01 to 26.4 GPH (0.04 to 100 LPH) |
Pressure Rating | 100 PSI |
Type | Peristaltic Pump |
Power Supply | 115V / 60Hz |
Material | PVC |
Explains the fixed cycle timer mechanism and its adjustable on-time cycles for specific models.
Details the variable speed adjustment for the A-100NF model, adjustable from 5% to 100%.
Describes the A-100NX model with no feed rate adjustment control.
Provides guidance on selecting an appropriate location for installing the pump, considering proximity to supply and electrical sources.
Details the procedure and considerations for mounting the pump using a floor mount configuration.
Outlines the steps and requirements for mounting the pump securely to a wall.
Details the FVS sensor's function of confirming fluid flow and triggering alarms if flow is not detected.
Explains the AL output, its sinking behavior, voltage, and current specifications for alarm conditions.
Describes the MA output, its sinking behavior, voltage, and current specifications for motor activity.
Provides a table detailing the wire color codes for connecting the pump motor to the power supply.
Presents a table mapping system descriptions to wire color codes for circuit board connections.
Illustrates the specific wiring connections for A-100NA and A-100NC models.
Shows the wiring diagram tailored for the A-100NS model.
Displays the wiring diagram for the A-100NF model, including speed adjustment connections.
Instructions for attaching the clear PVC suction tubing to the pump's inlet fitting.
Details how to attach the foot strainer and ceramic weight to the inlet tubing for sediment prevention.
Guides on connecting the opaque discharge tubing to the pump's outlet fitting.
Provides steps for installing the injection/check valve fitting into piping systems and connecting discharge tubing.
Explains how to adjust the on-time percentage for fixed cycle timer models using the control knob.
Details how to adjust the pumping speed percentage for variable speed models using the control knob.
Guides users on testing the TFD system's ability to detect specific chemicals.
Explains the open collector alarm signal provided by the TFD system for pump ruptures.
Details how to confirm the FVS sensor operates within its specified flow range for accurate detection.
Presents a table listing different FVS sensor models and their corresponding operating flow ranges.
Provides step-by-step instructions for physically installing the FVS sensor onto the pump inlet.
Outlines weekly inspection requirements for components to identify signs of wear or damage.
Details occasional cleaning and lubrication needs for pump parts like the head chamber and rollers.
Step-by-step instructions for safely disconnecting and removing the existing pump tube assembly.
Guides on inserting the new pump tube, ensuring proper alignment and securing it.
Explains how to determine warranty status and what parts/labor are covered and excluded.
Advises on necessary precautions when injecting chemicals and potential hazards.