BMP EUROPE Srl
Rev. 6
Installation and user manual Dynamicroll® Frigo 2
Type
Side left motor
Side right motor
Automation with inverter
400V BMP2_V04/05/06
Main supply
400 V AC / 230 V AC 3 PH
Frequency
50/60 Hz
Power line absorption
10 A 16 A
Heating cables absorption
4 A
Hot phon absorption (single-phase)
16 A
Motor power
0,75 - 1,5 2,2 kW
Control panel protection degree
IP65
Motor protection degree
IP54
Operating temperature
from -10 °C to +50 °C
Minimum temperature
-30°C
Maximum delta temperature
20°C
Motor type
Motor connection
W Brake
W Motor
Dispersion to
0,75 kW
453
10,8
0
1,50 kW
285
4,5
0
2,20 kW
301
2,9
0
In case of delta connection, change the motor connection to star and carry out the test.
NOTICE
230 V / 400 V Ø 4 mm
2
min.
Weight
The weight varies according to the size of the door. The weight of the door is indicated on the packaging.
Main components
A
Motor unit
B
Top heading
C
Columns
D
Curtain
E
Control panel
F
Hot blower