00.21
61 21 Filling and charging the battery
d Warning:
Battery acid is highly caustic.
Protect your eyes, face, hands, clothing and the
paintwork.
•
Disengage the rubber strap holding the battery.
•
Disconnect the battery breather hose.
•
Remove the battery.
•
Fill all the cells with pure battery acid of
density 1.28 to the Upper Level mark.
•
Allow the battery to stand for approximately
30 minutes.
•
The battery does not achieve full charge capacity
from being filled, so it has to be charged with a
battery charger.
L Note:
Follow the instructions for use supplied with the bat-
tery charger.
Charge current (A)
.........................10 % of rated battery capacity (Ah)
Charging time
..............................................................5-10 hours
•
Battery charge can be measured by checking
the density of the battery acid.
Acid density
Battery fully charged
............ 1.26-1.30 at a temperature of 20 °C (68 °F)
•
Shake the battery slightly to allow the gas bub-
bles to escape.
•
Wait until the battery acid has settled, check that
no more bubbles rise and if necessary, top up
the acid to the max. mark.
•
Reinstall the plugs.
•
Make a note of the charging date on the battery.
- UPPER LEVEL-
- LOWER LEVEL-
K14000460