Summary

Maintenance and Safety Precautions

Device Maintenance Guidelines

Information regarding the device's battery and repair policies, emphasizing user non-serviceability.

Critical Safety Warnings

Essential safety guidelines and precautions for using the massage gun, including usage restrictions.

FCC Compliance Information

Details on the device's compliance with FCC Rules, including conditions for operation and potential interference.

Disclaimer and General Advice

Medical Consultation Disclaimer

Advice to consult a physician before use, especially with pre-existing health conditions or recent surgery.

Device Overview and Components

Massage Gun Structure

Identification of key components including the massage head, gear indicator, power control, and charging port.

Massage Head Attachments

Description of the various interchangeable massage heads and their recommended uses.

Battery Status Indicators

Explanation of the LED lights indicating battery charge levels and low battery warnings.

Operating and Charging Instructions

Connecting and Using the Device

Step-by-step guide to attaching heads, powering on, adjusting speed levels, and shutting down the device.

Automatic Power-Off Features

Information on automatic shut-off after a set duration of operation or inactivity.

Device Charging Process

Detailed instructions on how to charge the massage gun, including cable requirements and full charge duration.

Troubleshooting and Technical Details

Troubleshooting Common Issues

Steps to resolve common problems, such as the device not working, focusing on charging and battery lights.

Technical Specifications

Key technical details of the massage gun, including speed, power, dimensions, voltage, and battery capacity.

Product Warranty Information

Details on the one-year warranty, including conditions that may void the warranty.

Muscle Therapy Protocols

Chest Massage Protocol

Instructions for massaging the chest muscles using the ball head attachment.

Upper Traps and Upper Back Protocol

Protocols for massaging the upper traps and upper back muscles.

Shoulder and Biceps Protocol

Protocols for massaging the shoulder and biceps muscles.

Triceps and Forearm Protocol

Protocols for massaging the triceps and forearm muscles.

Hand and Hip Flexor Protocol

Protocols for massaging the hand and hip flexor muscles.

Shin and Glute Protocol

Protocols for massaging the shin and glute muscles.

Hamstring and Calf Protocol

Protocols for massaging the hamstring and calf muscles.

Foot Massage Protocol

Instructions for massaging the foot muscles using the ball head attachment.

Customer Support and Contact

Product Support and Knowledge

Information on how to get help with device issues and gain product knowledge.

Returns, Refunds, and Orders

Guidance on initiating returns, refunds, and assistance with placing new orders.

Contact Us Details

Contact information for customer service, including phone number, email, and company address.

Overview

This document is the user manual for the Bob and Brad QL/DMS.T2-C Massage Gun.

Function Description

The Bob and Brad QL/DMS.T2-C Massage Gun is designed to provide percussive massage to accelerate muscle tissue responsiveness by increasing hydration, range of motion, and function to tight muscles. It can be used before, during, or after workouts for maximum benefits. The device features a removable and interchangeable massage head, allowing for customization based on the target muscle group and desired intensity. It offers multiple speed/level settings to cater to different massage needs, from warm-up and activation to deep tissue work and pain modulation. The device is equipped with a battery indicator to show the remaining power and automatically turns off after a period of operation or inactivity to conserve battery and ensure safety.

Important Technical Specifications

  • Product Name: Massage Gun
  • Product Model: QL/DMS.T2-C
  • Speed: 2000-3200 r/min (revolutions per minute)
  • Rated Power: 25W
  • Dimensions: 5.4" x 2.4" x 7.6"
  • Rated Voltage: 7.3V
  • Battery Capacity: 4000mAh
  • Charging Time: 270 minutes (approximately 4.5 hours for a full charge)
  • Average Working Time (full charge): Approximately 2-5 hours (varies depending on vibration frequency and massage pressure)
  • Charging Cable: USB-A to USB-C Cable (device will not charge with USB-C to USB-C cable)
  • Charger Output: Recommended 5V-2A

Usage Features

The massage gun offers intuitive operation with a single button for power and speed control.

  • Power On/Off: Long press the power button for 2 seconds to turn on and start at the first speed. Long press for 2 seconds from level 0 to shut down.
  • Speed Adjustment: Press the power button to switch between speeds 0-5.
  • Stop Output: When running in levels 1-5, press the power button for 2 seconds to stop the output (return to level 0).
  • Automatic Shut-off: The device automatically turns off after 10 minutes of continuous operation. It also shuts down after 20 seconds of inactivity when on standby (level 0).
  • Interchangeable Massage Heads: The device comes with five different massage heads, each designed for specific applications:
    • Fork Head: For longer muscles (calves, forearms, biceps, ankle/Achilles area).
    • Ball Head: For sore muscles and larger muscle groups (a great starter attachment).
    • Flat Head: For larger surface areas (quads, hamstrings, back, chest).
    • Bullet Head: For trigger points (glutes, hips, traps, shoulders, complex muscle groups).
    • Air Cushion Head: For sensitive areas (wrists, ankles, knees, traps, around the neck).
  • Installation/Removal of Heads: Massage heads are inserted completely with pressure until the buckle is in the slot. To remove, turn off the device and pull out the head. The Fork Head requires specific positioning for installation.
  • Massage Protocols: The manual provides specific protocols for various muscle groups, including Chest, Abs, Upper Traps, Upper Back, Shoulders, Biceps, Triceps, Forearm, Hands, Hip Flexors, Shins, Glutes, Hamstrings, Calves, and Feet. Each protocol specifies the recommended attachment (Ball Head or Flat Head), sweep pattern (A to B), duration per side, and total duration.
  • Vibration Frequencies: The device offers various vibration frequencies (levels 1-5) to achieve different effects:
    • Level 3 (Light to Moderate Pressure): Warm Up / Activation (30 sec or less, quick, high speed over area).
    • Level 4 (Heavy Pressure): Mid Workout / Myofascial Mobility (8-12 sec, target specific area, localized).
    • Level 1 or 2 (Moderate to Heavy Pressure): Recovery (90 sec or more, slow movement along the muscle).
    • Level 1 (Light Pressure): Pain Modulation (10-30 sec, relaxed, localized spot, over painful area).
    • All Levels (Light to Moderate Pressure): Body Awareness (10-20 sec, relaxed or with movement, over specific target area or movement over area).

Maintenance Features

  • Battery: The battery is not designed to be removed or exchanged by the user. Contact customer support for power supply issues.
  • Charging:
    • Fully charge new batteries before first use (approx. 4.5 hours).
    • Use the provided USB-A to USB-C cable for charging. USB-C to USB-C cables are not supported.
    • Connect the output end of the charging cable to the DC charging port at the bottom of the device, and the input end to a 5V/2A mobile power source or adapter.
    • The battery icon on the handle flickers during charging, indicating the charging process and remaining power. It stops flickering and remains on when fully charged (100%).
    • Charging can occur at any battery level, but the device must be shut down. Charging is automatically protected if the device is in operation.
  • Battery Indicator: Four LED lights indicate battery percentage:
    • LED1 (on): 25% remaining.
    • LED2 (on): 50% remaining.
    • LED3 (on): 75% remaining.
    • LED4 (on): 100% remaining.
    • LED1 flashing indicates battery is below 10% and requires recharging.
    • It is not recommended to deplete the battery below 25%.
  • Troubleshooting (if device stops working):
    • Recharge fully using the USB-A to USB-C cable for 3-4 hours.
    • Ensure battery lights are flickering during charge.
    • Press and hold the power button for 3-5 seconds.
  • Warranty: The product comes with a one-year warranty from the date of purchase. The warranty is voided if the device is damaged due to improper usage or storage, attempted repair or disassembly, or if the warranty period is exceeded.
  • Safety Precautions:
    • Do not attempt to open or repair the device; this voids the warranty.
    • Ensure supply voltage matches rating plate before connecting.
    • Do not submerge in water or other liquids.
    • Do not use for more than 30 minutes at a time; wait 5 minutes between sessions.
    • Do not apply directly to or around the head or genitals.
    • Consult a physician before use if experiencing unexplained pain, receiving medical treatment, or using medical equipment, or if pregnant, diabetic, epileptic, have migraines, herniated disks, spondylolisthesis, recent joint replacements, IUDs, or metal pins/plates in the body.

Bob and Brad QL/DMS.T2-C Specifications

General IconGeneral
BrandBob and Brad
ModelQL/DMS.T2-C
CategoryMassager
LanguageEnglish