148 S650 Operation & Maintenance Manual
HEATING, VENTILATION AND AIR CONDITIONING
(HVAC) (CONT’D)
Condenser
The condenser should be cleaned with the oil cooler and
the radiator. (See Cleaning on Page 155.)
Air Conditioning Lubrication
Run the air conditioning for about five minutes every
week to lubricate the internal components.
Troubleshooting
If the fan does not run, or the air conditioning does not
turn on, check the fuse. (See Fuse And Relay Location /
Identification on Page 158.) If the air conditioning system
circulates warm air, the refrigerant may need to be
recharged.
AIR CLEANER SERVICE
Replacing Filter Elements
Figure 208
It is important to change the air filter element only when
necessary. The service indicator (Item 1) will FLASH.
Press the information button (Item 3) until the display
screen (Item 2) shows the service codes. Service code
[M0117] (Air Filter Plugged) will show in the display
screen (Item 2) [Figure 208] when air filter change is
necessary.
Replace the inner filter every third time the outer filter is
replaced or as indicated.
Outer Filter
Figure 209
Open the latches (Item 1) and remove the dust cover
(Item 2) [Figure 209].
P-76460G
1
2
3
P100072
2
1

Related product manuals