EasyManua.ls Logo

Bodet BT6000 Series - Basketball Configuration Menu; Rule 1: FIBA; Rule 2: EB

Bodet BT6000 Series
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
Conguration menu per sport
The pre-recorded conguration for each sport can be modied. Select and validate a sport and a type of rules Hold down
the SEL (8) key to access to the conguration menu :
- Press the + or – (13) keys to modify the values of each parameter.
- Press the RIGHT (13) key to scroll down through all the parameters.
- Press the LEFT (13) key to scroll up.
- Press the OK (11) key to save the new parameters and return to the display of the match.
Basketball 6/7
Rule 1: FIBA Rule 2: EB Parameters Description
Shot timer duration
: 24 sec
24 sec
1 to 99 seconds Ball possession time 24 sec.
Shot timer end stp game
: Non
No
Yes or No
The countdown to 0 of the possession time stops or not the
main stopwatch.
Red light. end of priod
: Oui
No
Yes or No
If YES, the red led strip around the basketball boards will come
on at the end of the period
Red light. end of 24s
: Non
No
Yes or No
If YES, the red led strip around the basketball boards will come
on at the end of 24s
Yellow light. end of period
: Non
No
Yes or No
If YES, the red yellow strip around the basketball boards will
come on at the end of the period
Yellow light. end of 24s
: Non
Yes
Yes or No
If YES, the red yellow strip around the basketball boards will
come on at the end of 24s
Duration,before
game : 0 min
0 min
0 to 90 minutes
If = 0, no automatic countdown.
If > 0, the board will count down the programmed period, once the
sport has been validated.
Press “Start” to launch this countdown.
Horn before game
play : 0 min
0 min
0 to 90 minutes
Allow to signal with a short warning blast the next start of match. If
= 0, no horn.
Period Number
/game : 4
4
1 to 9 periods
Match with 1 to 9 periods.
Period duration
/game : 10 min
10 min
1 to 50 minutes
Duration of game periods.
Auto time break
duration : 0:00sec
0:00s
0 to 10 minutes
If = 0, no automatic countdown.
If > 0 the board will count down automatically the programmed time
to the end of the period.
Horn before time
brk end : 0 sec
0 sec
0 to 50 seconds
If = 0, no automatic horn.
If > 0, signal with a short blast the next start of match.
Half time
duration : 0 min
0 min
0 to 90 minutes
Programme the duration time if di󰀨erent from 15.
If = 0, no automatic interval.
Extra time
duration : 5 min
5 min
1 to 50 minutes
Selection of extra time period of match if there is a tie. A extra time
of 5 minutes repeatable if there is a tie.
Team foul maxi
cumul. : 5
5
1 to 9
Selection of maximum number of fouls cumulated.
Individual foul
number : 5
5
1 to 6
Choose limiting 1 to 6 individual player fouls before sending o󰀨 The
6th foul is only visible on the keyboard screen).
Time out
duration : 60 sec
60 sec
1 to 99 seconds
Choose the duration of time out.
Auto horn time
out end : No
No
Yes or No
If YES, the horn’s ringing automatically at each end of time out.
Horn before time
out end : 10 sec
10 sec
0 to 99 seconds
If = 0, no automatic horn.
If > 0, signal with a short blast at the next end of time out.
Time out 30 sec.
: No
Oui
Yes or No
If YES
Assigning a time HOME/GUEST
- Keys 12 or 12’ : display of the set value (default 60 sec.)
- Press to OK key : starts the time-out countdown
If NO
Assigning TO HOME/GUEST. Automatic stop at the end of the
countdown or pressing the corresponding key.
Player's number
HOME 4 : 4
4
1 to 99
Number of the 4th player.
Player's number
GUEST 15 : 15
15
1 to 99
Number of the 15th player.
Score per player
: Yes
Yes
Yes or No
If YES, the function point per player is active.
If NO, the function point per player is no active.
Horn
duration : 5 sec
5 sec
0 to 5 seconds
If = 0, no automatic horn.
If > 0, limit the duration of the horn’s ringing for reduce the sound
level in the room.
Keep display
result : 30sec
30 sec
10 to 60 seconds by step of
10
Maintains display of the last period for a programmable time if the
rest time is not programmed.
Factory data
load : No
No
Yes or No
If YES, reload the values of parameters as provided on putting the
display board into service.