Allgemeines.pm6.5 - USA
Page 1.1
General
BOGE Operating instructions for S 40-2...S 341 / SF 40-2...SF 220 series screw compressors
Safety instructions for
compressor operation
1.1 General safety instructions
WARNING!
Nonobservance of the following safety instructions may lead to injuries
and damage to the compressor.
Also observe the generally valid safety and accident prevention regu-
lations in addition to the information in these operating instructions!
1. Ensure that no commissioning or maintenance work on the compressor
be undertaken until these operating instructions are understood.
2. Only use the compressor for its intended use, as described in these op-
erating instructions.
3. The owner must ensure:
That only appropriately trained and authorized personnel work on this
compressor.
That the operating, maintenance and repair personnel has been made
fully familiar with all safety instructions, and that they are being observed
That the compressor is only operated in a safe operating condition.
4. Avoid any operating method which may impair the safety of the com-
pressor.
5. Do not exceed the limit value for the final compression pressure specified
on the type plate.
6. Do not operate the compressor without the attendant protection and
safety devices.
Do not dismantle any built-in safety devices or put them out of operation.
Ensure that all cladding and doors are closed prior to commissioning/
starting up the compressor and are not opened during operation.
7. Place the compressor out of operation as described in these operating
instructions, when dismantling the cladding or safety devices for repair
or maintenance work. Reattach all cladding and safety devices immedi-
ately upon completion of the repair or maintenance work.
8 Only operate the compressor using the additional equipment (options)
recommended or authorized by the manufacturer.
9. Undertake conversions and modifications of the compressor only in
agreement with BOGE, taking all relevant safety regulations into consid-
eration.
The manufacturer is not liable for damages resulting from independent
modifications on the compressor.
10. Never start compressor when one or serveral parts (e.g. cable, plug) are
damaged, when not in perfect working order or when damage is detected
or suspected.
11. Observe all safety and danger signs directly attached on the compressor!
12. The compressed air-oil pressure receiver has to be inspected in pre-
determined intervals according to the local authorities responsible for
pressure receivers.
13. To avoid damages, special precautions have to be taken during (re-)
operation of compressors with frequency control, if the frequency con-
verter was cut off from the power supply for a longer period of time
(> 12 months). In this case please contact the BOGE-Service.