4
RIVKLE
®
blind rivet nut Setting methods
2 - Installation force value
The setting force is defined using combination of:
RIVKLE
®
installation parameters defined by our laboratory
Application parameter (tensile strength after assembly and during service)
2-1 RIVKLE
®
Installation parameters
Maximum thickness
(
C1
)
Minimum thickness
(
C2
)
Setting range
= Force to obtain
good installation
Force
Stroke
Tolerance
Tolerance
Stroke in max thickness
Stroke in min thickness
C1:
set in maximum
thickness
C2:
set in minimum
thickness
Min
Max