Summary

Part Ⅰ: Technical Information

2. Specifications

Details the technical specifications and operational parameters of the air conditioner units.

5. Electrical Part

Details the electrical components, wiring diagrams, and PCB layouts.

5.1 Wiring Diagram

Outlines the electrical connections for the indoor and outdoor units.

6. Function and Control

Explains various operational modes, control functions, and features.

Part Ⅱ: Installation and Maintenance

Safety Precautions for Installing and Relocating the Unit

Highlights critical safety measures to follow during unit installation and relocation.

8. Installation

Covers the step-by-step process for installing the air conditioning unit.

8.4 Requirements for Electric Connection

Outlines the electrical safety regulations and connection requirements.

8.7 Vacuum Pumping and Leak Detection

Explains the process of vacuum pumping and detecting refrigerant leaks.

8.8 Check after Installation and Test Operation

Details the final checks and operational tests after installation.

9. Maintenance

Covers routine maintenance, cleaning, and inspection procedures.

9.1 Error Code List

Lists all error codes, their display methods, and possible causes.

9.2 Troubleshooting for Main Malfunction

Provides diagnostic steps for major system malfunctions and errors.

1. Malfunction of Temperature Sensor F1, F2

Guides troubleshooting for temperature sensor faults in the indoor unit.

2. Malfunction of Blocked Protection of IDU Fan Motor H6

Details troubleshooting steps for a blocked indoor fan motor protection error.

6. Malfunction of Insufficient fluorine protection F0

Provides troubleshooting steps for insufficient fluorine protection errors.

7. Communication malfunction E6

Outlines troubleshooting steps for communication errors between indoor and outdoor units.

8. Malfunction of Overcurrent Protection E5

Details troubleshooting procedures for overcurrent protection faults.

(2) IPM protection, phase current overcurrent (the control board as below indicates the control board of outdoor unit) H5;P5

Troubleshoots IPM protection and phase current overcurrent issues in the outdoor unit.

(4) Start-up failure (following AP1 for outdoor unit control board)

Guides troubleshooting for start-up failures in the outdoor unit.

(6) Overload and air exhaust malfunction diagnosis (following AP1 for outdoor unit control board)

Troubleshoots overload and air exhaust malfunctions in the outdoor unit.

Boreal brisa BRS24HPJ1IA Specifications

General IconGeneral
RefrigerantR410A
TypeSplit System
Cooling Capacity24000 BTU
Heating Capacity24000 BTU
Power Supply1-phase, 50/60Hz
Weight (Indoor Unit)10 kg
Weight (Outdoor Unit)42 kg

Related product manuals