Fan 1900, Fan 1900 DH 13
with regard to the required installation position,
by inserting the power cord into the housing
Measures shall be taken to prevent gases from escaping from open smoke duct or other open ame
equipment into the room�
Unauthorised changes or modications to the equipment are not permitted
Before installing the equipment, check the load-bearing capacity of the structure to which it is to be
mounted, as improper mounting can lead to damage or destruction of the equipment and can pose
a risk to persons in the vicinity of the equipment in the following situations�
The appliance may become dangerous
if used improperly or if installed by unqualied personnel.
3 APPLICATION AND OPERATING CONDITIONS
The fan is designed for wall and ceiling mounting
Bathroom extractor fans are designed to transport normal or slightly dusty air (particle size <10 μm)
of low aggressiveness and humidity in temperate climates according to and within their limits
of performance�
The appliance is designed only for continuous operation in a building if there is no access
to the power supply line�
The maximum temperature handled by the bathroom extractor fan and the maximum ambient
temperature are +40°C�
The exhaust fan is an IP24 and protection class II device if it is installed in the wall or ceiling according
to Figure 7 and Appendix 1�
The bathroom extractor fan must be operated according to its intended use and in accordance
with the data provided on the rating plate�
The bathroom extractor fan must be connected to the building mains (recessed electrical installation)
with one of the following power cable: 2x1,5 mm
2
; 3x1,5 mm
2
, depending on the fan version - see
chapter 5� If a cable with more wires is used, e�g� 4x1,5mm
2
, the outer diameter of the cable must not
exceed 14,5 mm�
The bathroom extractor fan cannot be used to circulate air with the following characteristics:
-viscous contaminants prone to deposition in the bathroom extractor fan,
-corrosive contaminants which may degrade the bathroom extractor fan,
-contaminants from mixtures of ammable substances in the form of gases, vapours, mists
and dusts, which in combination with air can create an explosive atmosphere
Motors tted with ball bearings are designed for a service life of at least 30,000 hours at maximum
permissible ambient temperature so as to enable continuous operation at maximum eciency�
In case additional controllers exist in the installation, these must not cause frequent switching on and
o of the bathroom extractor, as this will be considered extreme and not intended use of the product�
The device is not suitable for use 2000 m above sea level�