EasyManua.ls Logo

Bosch B20CS50 Series - Page 14

Bosch B20CS50 Series
71 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
1. A/S Defrosting Mode (Heater defrost Pause Fan Delay)
INPUT CONTROL OBJECT
CONTENTS REMARKS
1. Defrosting Cycle
1. Comp
2. F-Fan
3. R-Fan
4. D-Heater
Heater
Defrosting
1) Comp, F-fan, R-fan : OFF
D-Heater : ON
2) Time limit
30 seconds : Heater is ON regardless of D-sensor
temperature right after defrosting start
30 minutes : in case of D1-Error
80 minutes : in normal control state
3) If D-sensor 13, Heater Defrosting is OFF
Pause
Time : 7 minutes
Comp, F-fan, R-fan, Heater etc. : OFF
Fan-Delay
1) Time : 5 minutes
Comp : ON
F-fan, R-fan, Heater : OFF
Pause
Fan-Delay
Heater
Defrosting
2. How to start
; In “Lock” mode, push “Refrigerator Set” button 5 times while pushing “Freezer Set”
button simultaneously.
3. How to proceed
1) same as normal defrosting
2) Heater is ON regardless of D-sensor temp. at first 30 seconds.
(Check of defrosting current)
4-3. Forced Defrosting Mode
1. Fan voltage of control mode
INPUT CONTROL OBJECT
CONTENTS REMARKS
1. F-Sensor
2. R-Sensor
1. F-FAN, R-FAN, C-FAN
13 V13 V13 VVoltage
CondenserRefrigeratorFreezerFAN
4-4. Fan Voltage of Control Mode

Related product manuals