Bosch FHP EC120 - Model Nomenclature

Bosch FHP EC120
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model Nomenclature | 3EC Series
T111970289 (2015/01)EC Series
MODEL NOMENCLATURE
Figure # 1
EC 300- 4VTC-SBSIUA-XXTXXXXXX 1XXX
X
6XXX XS B A
EC CODE STRING LEVEL
SIZE B - Bosch
072 STANDARD/SPECIAL
096 S - Standard
120 A - Special #1
150 B - Special #2
180 OPEN
210 MOTOR BLOWER ORIENTATION
240 X - Blower and Motor Standard Orientation
300 B - Blower Rotated 180 Deg, Motor Standard
360 M - Blower Standard, Motor Rotated
1
VOLTAGE N - Both Blower and Motor Rotated 180 Deg
1 208-230/60/1 X - N/A
3 208-230/60/3 MOTOR HP (BELT DRIVE ONLY)
4460/60/3 A - 1
5 575/60/3 B - 1.5
CABINET CONFIGURATION C - 2
VT - Vertical D - 3
HZ - Horizontal E - 5
COAX OPTIONS AIR FILTRATION
C - Copper 1 - Standard Throw Away
N - Cupro-Nickel 3 - 2" 4 Sided Filter Rack with 1" Filter
X - No condenser 8 - 2" 2 Sided Filter Rack
WATER CONNECTIONS OPEN
F - Front ECONOMIZER
S - Side X - None
X - N/A E - Economizer With 3 Way Valve and Contr
ols
RETURN AIR CONFIGURATION H - Hot Water Coil
B - Back X - None
F - Front CONTROLS
L - Left X - Standard
R - Right M - DDC - Multi-Protocol (BacNET, Modbus, N2)
DISCHARGE AIR CONFIGURATION P - DDC - Multi-Protocol (BacNET, Modbus, N2) w/ Expander
T - Top L - DDC - LonWorks
F - Front G - DDC - LonWorks w/ Expander
R - Rear I - Inverter
E - End Blow J - DDC - Multi-Protocol (BacNET, Modbus, N2) with Inverter
S - Straight Through T - DDC - Multi-Protocol (BacNET, Modbus, N2) with Inver
ter w/ Expander
FAN/MOTOR OPTIONS K - DDC - LonWorks with Inverter
I - Belt Drive, Inverter Duty C - DDC - LonWorks with Inverter
B - Belt Drive O - Carrier Open Protocol Controller
AIR COIL V - Carrier Open Protocol Controller w/ Inverter
U - Uncoated TRANSFORMER
D - DuoGuard 7 - 75 VA
REVISION LEVEL 1 - 100 VA
A - Current REFRIGERATION CIRCUIT OPTIONS
ELECTRIC HEAT X - None
X - None H - Hot Gas Reheat - On/O
CABINET CONSTRUCTION B - Hot Gas Bypass
A - G90 Steel / 1/2" Standard 1.5LB Dual Density Fiberglass C - Hot Gas Bypass with Hot Gas Reheat
C - G90 Steel / 1/2" Closed Cell Foam M - Modulating Hot Gas Reheat
D - G90 Steel / 1/2" Standard 1.5LB Dual Density Fiberglass, Extra Quiet S - Straight Cool
F - G90 Steel / 1/2" Closed Cell Foam, Extra Quiet GENERAL ELECTRICAL OPTIONS(UP TO 5 AVAILABLE PER UNIT
APPLICATION A - EMS relay D - Phase Monitor G - Boilerless control X - As default for non used electrical codes
T - TXV Option B - B
lower Monitor Relay E - Pump/valve relay H - Flow proving switch Z - EMS + Pump/valve relay
G - EXTENDED RANGE W/ SCHRADER VALVE (Geothermal) C - Compressor Monitor Relay M - Wire to 208 V K - Fire Alarm Relay/Dual Power