Loading...
English | 17
Vibration total values a
h
(triax vector sum) and uncertainty K
determined according toEN60745-2-23:
Surface grinding (roughing with grinding tool diameter of
25mm):
a
h
=5.6m/s
2
K=1.5m/s
2
The vibration level given in these instructions has been
measured in accordance with a standardised measuring pro-
cedure and may be used to compare power tools. It can also
be used for a preliminary estimation of exposure to vibra-
tion.
The stated vibration level applies to the main applications of
the power tool. However, if the power tool is used for differ-
ent applications, with different application tools or poorly
maintained, the vibration level may differ. This can signific-
antly increase the exposure to vibration over the total work-
ing period.
To estimate the exposure to vibration accurately, the times
when the tool is switched off or when it is running but not ac-
tually being used should also be taken into account. This can
significantly reduce the exposure to vibration over the total
working period.
Implement additional safety measures to protect the oper-
ator from the effects of vibration, such as servicing the
power tool and application tools, keeping the hands warm,
and organising workflows correctly.
Fitting
u Remove the battery from the power tool before carry-
ing out work on the power tool (e.g. maintenance,
changing tool, etc.). The battery should also be re-
moved for transport and storage. There is risk of injury
from unintentionally pressing the on/off switch.
Using the GCY 30-4 Bluetooth
®
Low Energy
Module
Note: The GCY 30-4 Bluetooth
®
Low Energy Module is avail-
able as an accessory with GGS 18V-23 LC power tools.
Read the corresponding operating instructions for informa-
tion about the GCY30-4 Bluetooth
®
Low Energy Module.
Charging the Battery
u Use only the chargers listed in the technical data. Only
these chargers are matched to the lithium-ion battery of
your power tool.
Note: The battery is supplied partially charged. To ensure
full battery capacity, fully charge the battery in the charger
before using your power tool for the first time.
The lithium-ion battery can be charged at any time without
reducing its service life. Interrupting the charging process
does not damage the battery.
The lithium-ion battery is protected against deep discharge
by the "Electronic Cell Protection (ECP)". When the battery
is discharged, the power tool is switched off by means of a
protective circuit: The application tool no longer rotates.
u Do not continue to press the On/Off switch after the
power tool has automatically switched off. The battery
can be damaged.
Follow the instructions on correct disposal.
Removing the Battery
The battery (7) is equipped with two locking levels to pre-
vent the battery from falling out when pushing the battery re-
lease button (6) unintentionally. As long as the battery is in-
serted in the power tool, it is held in position by means of a
spring.
To remove the battery(7), press the release button(6) and
pull the battery out of the power tool. Do not use force to
do this.
Battery charge indicator
The green LEDs on the battery charge indicator indicate the
state of charge of the battery. For safety reasons, it is only
possible to check the state of charge when the power tool is
not in operation.
Press the button for the battery charge indicator or to
show the state of charge. This is also possible when the bat-
tery is removed.
If no LED lights up after pressing the button for the battery
charge indicator, then the battery is defective and must be
replaced.
Battery model GBA 18V...
LEDs Capacity
3× continuous green light 60−100%
2× continuous green light 30−60%
1× continuous green light 5−30%
1× flashing green light 0−5%
Battery model ProCORE18V...
LEDs Capacity
5× continuous green light 80−100%
4× continuous green light 60−80%
3× continuous green light 40−60%
2× continuous green light 20−40%
1× continuous green light 5−20%
1× flashing green light 0−5%
Fitting the Abrasive Tools (see figure A)
u Remove the battery from the power tool before carry-
ing out work on the power tool (e.g. maintenance,
changing tool, etc.). The battery should also be re-
Bosch Power Tools 1 609 92A 6DN | (15.06.2021)