EasyManua.ls Logo

Bosch GLM 100 C - Page 31

Bosch GLM 100 C
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-31-
Deleting Measured Values
Briefly pressing button 4 deletes the last individual measuring value
determined in any measuring function. Briefly pressing the button
repeatedly deletes the individual measuring values in reverse order.
To delete the currently displayed measured-value list entry, briefly press
button 4. To delete the complete measured-value list and the constant
CST”, press and hold the measured value list button 7 and at the same
time briefly press button 4.
In wall surface measurement mode, briefly pressing button 4 the first time
deletes the last individually measured value; pressing the button a second
time deletes all lengths B
X
, and pressing the button a third time deletes
the room height A.
Adding Measured Values
To add measured values, first carry out any measurement or select an
entry from the measured-value list. Then press the plus button 11.
For confirmation, “+” appears on the display. Then carry out a second
measurement or select another entry from the measured-value list.
To call up the sum of both measurements, press the result
button 6. The calculation is indicated in the measured-
value lines a, and the sum in the result line c.
After calculation of the sum, further measured values
or measured-value list entries can be added to this
result when pressing the plus button 11 prior to each
measurement.
Pressing the result button 6 ends the addition.
Notes on the addition:
Mixed length, area and volume values cannot be added together. For
example, when a length and area value are added, “ERROR” briefly
appears on the display after pressing the result button 6. Afterwards, the
measuring tool switches back to the last active measuring mode.
For each calculation, the result of one measurement is added (e.g. the
volume value); for continuous measurements, this would be the displayed
measured value in result line c. The addition of individual measured
values from the measured-value lines a is not possible.

Other manuals for Bosch GLM 100 C

Related product manuals