Installation instructions
29
Greentherm T9900 SE/i – 6 720 813 635 (2019/03)
Fig. 15 Horizontal venting installation air intake piping not
shown)
[1] Termination
[2] Water heater
[3] Elbow
[4] Horizontal run should slope ¼" per foot upwards to water
heater
[LA] 12 inches (305 mm) (18 in. for Canada) above maximum
snow level or at least 24 inches (610 mm), whichever is
greater
NOTICE:
Place pipe supports every 5 feet (1525mm) of horizontal
and vertical run, beginning with support near water heater.
Periodic cleaning of the vent terminal and air intake screens
is mandatory.
Avoid locating vent terminals near equipment, vegetation,
plants or building features which can be subject to
degradation from exhaust gases.
Fig. 16 Horizontal venting system (sealed combustion)
[1] Intake
[2] Exhaust
Fig. 17 Vent and air intake pipe position of a sealed
combustion system
[1] Intake
[2] Exhaust
[X] At least 1foot (305mm)